This page is part of the FHIR Specification (v4.4.0: R5 Preview #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Orders and Observations Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw JSON (canonical form + also see JSON Format Specification)
Example definition of serum or plasma specimen.
{ "resourceType": "SpecimenDefinition", "id": "2364", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: 2364</p><p><b>status</b>: active</p><p><b>typeCollected</b>: Venous blood specimen <span>(Details : {SNOMED CT code '122555007' = 'Venous blood specimen', given as 'Venous blood specimen'})</span></p><p><b>patientPreparation</b>: 12 hour fasting <span>(Details )</span>, At rest <span>(Details : {SNOMED CT code '263678003' = 'At rest', given as 'At rest'})</span></p><p><b>timeAspect</b>: preferrably morning time</p><blockquote><p><b>typeTested</b></p><p><b>type</b>: Serum specimen <span>(Details : {SNOMED CT code '119364003' = 'Serum specimen', given as 'Serum specimen'})</span></p><p><b>preference</b>: preferred</p><h3>Containers</h3><table><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>plastic <span>(Details : {SNOMED CT code '61088005' = 'Plastic', given as 'plastic'})</span></td><td>Evacuated blood collection tube, thrombin/clot activator/gel separator <span>(Details : {SNOMED CT code '702281005' = 'Evacuated blood collection tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube, thrombin/clot activator/gel separator'})</span></td><td>yellow cap <span>(Details : {urn:iso:std:iso:6710:2017 code 'yellow' = 'yellow', given as 'yellow cap'})</span></td><td>2 ml<span> (Details: UCUM code mL = 'mL')</span></td></tr></table><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Ambient temperature <span>(Details )</span></p><p><b>temperatureRange</b>: 15-25 °C</p><p><b>maxDuration</b>: 60 minute<span> (Details: UCUM code min = 'min')</span></p></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Refrigerated temperature <span>(Details )</span></p><p><b>temperatureRange</b>: 2-8 °C</p><p><b>maxDuration</b>: 8 hour<span> (Details: UCUM code h = 'h')</span></p></blockquote></blockquote><blockquote><p><b>typeTested</b></p><p><b>type</b>: Plasma specimen <span>(Details : {SNOMED CT code '119361006' = 'Plasma specimen', given as 'Plasma specimen'})</span></p><p><b>preference</b>: alternate</p><h3>Containers</h3><table><tr><td>-</td><td><b>Material</b></td><td><b>Type</b></td><td><b>Cap</b></td><td><b>MinimumVolume[x]</b></td></tr><tr><td>*</td><td>glass <span>(Details : {SNOMED CT code '32039001' = 'Glass', given as 'glass'})</span></td><td>Evacuated blood collection tube, thrombin/clot activator/gel separator <span>(Details : {SNOMED CT code '702281005' = 'Evacuated blood collection tube, thrombin/clot activator/gel separator', given as 'Evacuated blood collection tube, thrombin/clot activator/gel separator'})</span></td><td>green cap <span>(Details : {urn:iso:std:iso:6710:2017 code 'green' = 'green', given as 'green cap'})</span></td><td>2 ml<span> (Details: UCUM code mL = 'mL')</span></td></tr></table><p><b>rejectionCriterion</b>: insufficient specimen volume <span>(Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'insufficient' = 'insufficient specimen volume', given as 'insufficient specimen volume'})</span>, hemolized specimen <span>(Details : {http://terminology.hl7.org/CodeSystem/rejection-criteria code 'hemolized' = 'hemolized specimen', given as 'hemolized specimen'})</span></p><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Ambient temperature <span>(Details )</span></p><p><b>temperatureRange</b>: 15-25 °C</p><p><b>maxDuration</b>: 60 minute<span> (Details: UCUM code min = 'min')</span></p></blockquote><blockquote><p><b>handling</b></p><p><b>temperatureQualifier</b>: Refrigerated temperature <span>(Details )</span></p><p><b>temperatureRange</b>: 2-8 °C</p><p><b>maxDuration</b>: 8 hour<span> (Details: UCUM code h = 'h')</span></p></blockquote></blockquote></div>" }, "status": "active", "typeCollected": { "coding": [ { "system": "http://snomed.info/sct", "code": "122555007", "display": "Venous blood specimen" } ] }, "patientPreparation": [ { "text": "12 hour fasting" }, { "coding": [ { "system": "http://snomed.info/sct", "code": "263678003", "display": "At rest" } ] } ], "timeAspect": "preferrably morning time", "typeTested": [ { "type": { "coding": [ { "system": "http://snomed.info/sct", "code": "119364003", "display": "Serum specimen" } ] }, "preference": "preferred", "container": { "material": { "coding": [ { "system": "http://snomed.info/sct", "code": "61088005", "display": "plastic" } ] }, "type": { "coding": [ { "system": "http://snomed.info/sct", "code": "702281005", "display": "Evacuated blood collection tube, thrombin/clot activator/gel separator" } ] }, "cap": { "coding": [ { "system": "urn:iso:std:iso:6710:2017", "code": "yellow", "display": "yellow cap" } ] }, "minimumVolumeQuantity": { "value": 2, "unit": "ml", "system": "http://unitsofmeasure.org", "code": "mL" } }, "handling": [ { "temperatureQualifier": { "text": "Ambient temperature" }, "temperatureRange": { "low": { "value": 15, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" }, "high": { "value": 25, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" } }, "maxDuration": { "value": 60, "unit": "minute", "system": "http://unitsofmeasure.org", "code": "min" } }, { "temperatureQualifier": { "text": "Refrigerated temperature" }, "temperatureRange": { "low": { "value": 2, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" }, "high": { "value": 8, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" } }, "maxDuration": { "value": 8, "unit": "hour", "system": "http://unitsofmeasure.org", "code": "h" } } ] }, { "type": { "coding": [ { "system": "http://snomed.info/sct", "code": "119361006", "display": "Plasma specimen" } ] }, "preference": "alternate", "container": { "material": { "coding": [ { "system": "http://snomed.info/sct", "code": "32039001", "display": "glass" } ] }, "type": { "coding": [ { "system": "http://snomed.info/sct", "code": "702281005", "display": "Evacuated blood collection tube, thrombin/clot activator/gel separator" } ] }, "cap": { "coding": [ { "system": "urn:iso:std:iso:6710:2017", "code": "green", "display": "green cap" } ] }, "minimumVolumeQuantity": { "value": 2, "unit": "ml", "system": "http://unitsofmeasure.org", "code": "mL" } }, "rejectionCriterion": [ { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/rejection-criteria", "code": "insufficient", "display": "insufficient specimen volume" } ] }, { "coding": [ { "system": "http://terminology.hl7.org/CodeSystem/rejection-criteria", "code": "hemolized", "display": "hemolized specimen" } ] } ], "handling": [ { "temperatureQualifier": { "text": "Ambient temperature" }, "temperatureRange": { "low": { "value": 15, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" }, "high": { "value": 25, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" } }, "maxDuration": { "value": 60, "unit": "minute", "system": "http://unitsofmeasure.org", "code": "min" } }, { "temperatureQualifier": { "text": "Refrigerated temperature" }, "temperatureRange": { "low": { "value": 2, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" }, "high": { "value": 8, "unit": "°C", "system": "http://unitsofmeasure.org", "code": "Cel" } }, "maxDuration": { "value": 8, "unit": "hour", "system": "http://unitsofmeasure.org", "code": "h" } } ] } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.