Release 5 Preview #2

This page is part of the FHIR Specification (v4.4.0: R5 Preview #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-satO2.xml

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile) (id = "satO2")

<?xml version="1.0" encoding="UTF-8"?>

<Observation xmlns="http://hl7.org/fhir">
  <id value="satO2"/> 
  <meta> 
    <profile value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/> 
  </meta> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : satO2</p> <p> <b> meta</b> : </p> <p> <b> identifier</b> : o1223435-10</p> <p> <b> partOf</b> : <a> Procedure/ob</a> </p> <p> <b> status</b> : final</p> <p> <b> category</b> : Vital Signs <span> (Details : {http://terminology.hl7.org/CodeSystem/observation-category code 'vital-signs'
           = 'Vital Signs', given as 'Vital Signs'})</span> </p> <p> <b> code</b> : Oxygen saturation in Arterial blood <span> (Details : {LOINC code '2708-6' = 'Oxygen saturation in Arterial blood', given as 'Oxygen
           saturation in Arterial blood'}; {LOINC code '59408-5' = 'Oxygen saturation in Arterial
           blood by Pulse oximetry', given as 'Oxygen saturation in Arterial blood by Pulse oximetry'};
           {urn:iso:std:iso:11073:10101 code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})</span> </p> <p> <b> subject</b> : <a> Patient/example</a> </p> <p> <b> effective</b> : 05/12/2014 7:30:10 PM</p> <p> <b> value</b> : 95 %<span>  (Details: UCUM code % = '%')</span> </p> <p> <b> interpretation</b> : Normal (applies to non-numeric results) <span> (Details : {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation code 'N'
           = 'Normal', given as 'Normal'})</span> </p> <p> <b> device</b> : <a> DeviceMetric/example</a> </p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 90 %<span>  (Details: UCUM code % = '%')</span> </td> <td> 99 %<span>  (Details: UCUM code % = '%')</span> </td> </tr> </table> </div> </text> <identifier> 
    <system value="http://goodcare.org/observation/id"/> 
    <value value="o1223435-10"/> 
  </identifier> 
  <partOf> 
    <reference value="Procedure/ob"/> 
  </partOf> 
  <status value="final"/> 
  <category> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/observation-category"/> 
      <code value="vital-signs"/> 
      <display value="Vital Signs"/> 
    </coding> 
    <text value="Vital Signs"/> 
  </category> 
  <code> 
    <coding> 
      <system value="http://loinc.org"/> 
      <!--    LOINC    -->
      <code value="2708-6"/> 
      <display value="Oxygen saturation in Arterial blood"/> 
    </coding> 
    <!--    Example of a translation to a more specific code  to the vitals profile LOINC code
        -->
    <coding> 
      <system value="http://loinc.org"/> 
      <!--    LOINC    -->
      <code value="59408-5"/> 
      <display value="Oxygen saturation in Arterial blood by Pulse oximetry"/> 
    </coding> 
    <!--    Example of a translation to a more specific code  to the vitals profile LOINC code
        -->
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <!--       mdc       -->
      <code value="150456"/> 
      <display value="MDC_PULS_OXIM_SAT_O2"/> 
    </coding> 
  </code> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <effectiveDateTime value="2014-12-05T09:30:10+01:00"/> 
  <valueQuantity> 
    <value value="95"/> 
    <unit value="%"/> 
    <system value="http://unitsofmeasure.org"/> 
    <code value="%"/> 
  </valueQuantity> 
  <interpretation> 
    <coding> 
      <system value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/> 
      <code value="N"/> 
      <display value="Normal"/> 
    </coding> 
    <text value="Normal (applies to non-numeric results)"/> 
  </interpretation> 
  <device> 
    <reference value="DeviceMetric/example"/> 
  </device> 
  <referenceRange> 
    <low> 
      <value value="90"/> 
      <unit value="%"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="%"/> 
    </low> 
    <high> 
      <value value="99"/> 
      <unit value="%"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="%"/> 
    </high> 
  </referenceRange> 
</Observation> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.