Release 5 Preview #2

This page is part of the FHIR Specification (v4.4.0: R5 Preview #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f206-staphylococcus.json

Orders and Observations Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Real-world patient - staphylococcus

{
  "resourceType": "Observation",
  "id": "f206",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f206</p><p><b>status</b>: final</p><p><b>code</b>: Blood culture <span>(Details : {http://acmelabs.org code '104177' = '104177', given as 'Blood culture'}; {LOINC code '600-7' = 'Bacteria identified in Blood by Culture', given as 'Bacteria identified in Blood by Culture'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>issued</b>: 11/03/2013 8:28:00 PM</p><p><b>performer</b>: <a>Luigi Maas</a></p><p><b>value</b>: Staphylococcus aureus <span>(Details : {SNOMED CT code '3092008' = 'Staphylococcus aureus', given as 'Staphylococcus aureus'})</span></p><p><b>interpretation</b>: Positive <span>(Details : {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation code 'POS' = 'Positive)</span></p><p><b>method</b>: Blood culture for bacteria, including anaerobic screen <span>(Details : {SNOMED CT code '104177005' = 'Blood culture for bacteria, including anaerobic screen', given as 'Blood culture for bacteria, including anaerobic screen'})</span></p></div>"
  },
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://acmelabs.org",
        "code": "104177",
        "display": "Blood culture"
      },
      {
        "system": "http://loinc.org",
        "code": "600-7",
        "display": "Bacteria identified in Blood by Culture"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f201",
    "display": "Roel"
  },
  "issued": "2013-03-11T10:28:00+01:00",
  "performer": [
    {
      "reference": "Practitioner/f202",
      "display": "Luigi Maas"
    }
  ],
  "valueCodeableConcept": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "3092008",
        "display": "Staphylococcus aureus"
      }
    ]
  },
  "interpretation": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
          "code": "POS"
        }
      ]
    }
  ],
  "method": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "104177005",
        "display": "Blood culture for bacteria, including anaerobic screen"
      }
    ]
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.