This page is part of the FHIR Specification (v4.4.0: R5 Preview #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Standards Status: Informative | Compartments: Not linked to any defined compartments |
Raw Turtle (+ also see Turtle/RDF Format Specification)
Generic Formulation - Lorazepam 2mg/ml injection
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Medication/med0313> a fhir:Medication; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "med0313"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: med0313</p><p><b>code</b>: Lorazepam 2mg/ml injection solution 1ml vial (product) <span>(Details : {SNOMED CT code '400621001' = 'Lorazepam 2mg/mL injection solution 1mL vial', given as 'Lorazepam 2mg/ml injection solution 1ml vial (product)'})</span></p><p><b>doseForm</b>: Injection solution (qualifier value) <span>(Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection solution (qualifier value)'})</span></p><p><b>amount</b>: 1 ml<span> (Details: UCUM code ml = 'ml')</span>/1 vial<span> (Details: http://terminology.hl7.org/CodeSystem/medicationknowledge-package-type code vial = 'Vial')</span></p><h3>Ingredients</h3><table><tr><td>-</td><td><b>Item</b></td><td><b>Strength[x]</b></td></tr><tr><td>*</td><td/><td>2 mg<span> (Details: UCUM code mg = 'mg')</span>/1 mL<span> (Details: UCUM code mL = 'mL')</span></td></tr></table></div>" ]; fhir:Medication.code [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:400621001; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "400621001" ]; fhir:Coding.display [ fhir:value "Lorazepam 2mg/ml injection solution 1ml vial (product)" ] ] ]; fhir:Medication.doseForm [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:385219001; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "385219001" ]; fhir:Coding.display [ fhir:value "Injection solution (qualifier value)" ] ] ]; fhir:Medication.amount [ fhir:Ratio.numerator [ fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "ml" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "ml" ] ]; fhir:Ratio.denominator [ fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ]; fhir:Quantity.system [ fhir:value "http://terminology.hl7.org/CodeSystem/medicationknowledge-package-type" ]; fhir:Quantity.code [ fhir:value "vial" ] ] ]; fhir:Medication.ingredient [ fhir:index 0; fhir:Medication.ingredient.item [ fhir:CodeableReference.concept [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:387106007; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "387106007" ]; fhir:Coding.display [ fhir:value "Lorazepam (substance)" ] ] ] ]; fhir:Medication.ingredient.strengthRatio [ fhir:Ratio.numerator [ fhir:Quantity.value [ fhir:value "2"^^xsd:decimal ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mg" ] ]; fhir:Ratio.denominator [ fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mL" ] ] ] ] . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Medication/med0313.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/Medication/med0313.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.