This page is part of the FHIR Specification (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3
Vocabulary Work Group | Maturity Level: N/A | Standards Status: Informative |
Raw XML (canonical form + also see XML Format Specification)
FHIR Value set/code system definition for HL7 v2 table 0472 ( TQ Conjunction ID)
<?xml version="1.0" encoding="UTF-8"?> <ValueSet xmlns="http://hl7.org/fhir"> <id value="v2-0472"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/> </meta> <language value="en"/> <text> <status value="additional"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p> TQ Conjunction ID</p> <table class="grid"> <tr> <td> <b> Code</b> </td> <td> <b> Description</b> </td> <td> <b> Comment</b> </td> <td> <b> Version</b> </td> </tr> <tr> <td> A <a name="A"> </a> </td> <td> Asynchronous</td> <td> Do the next specification in parallel with this one (unless otherwise constrained by the following fields: TQ1-7-start date/time and TQ1-8-end date/time). The conjunction of "A" specifies two parallel instructions, as are sometimes used in medication, e.g., prednisone given at 1 tab on Monday, Wednesday, Friday, and at 1/2 tab on Tuesday, Thursday, Saturday, Sunday.</td> <td> added v2.4</td> </tr> <tr> <td> C <a name="C"> </a> </td> <td> Actuation Time</td> <td> It will be followed by a completion time for the service. This code allows one to distinguish between the time and priority at which a service should be actuated (e.g., blood should be drawn) and the time and priority at which a service should be completed (e.g., results should be reported).</td> <td> added v2.4</td> </tr> <tr> <td> S <a name="S"> </a> </td> <td> Synchronous</td> <td> Do the next specification after this one (unless otherwise constrained by the following fields: TQ1-7-start date/time and TQ1-8-end date/time). An "S" specification implies that the second timing sequence follows the first, e.g., when a service request is written to measure blood pressure Q15 minutes for the 1st hour, then every 2 hours for the next day.</td> <td> added v2.4</td> </tr> </table> </div> </text> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status"> <valueCode value="external"/> </extension> <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm"> <valueInteger value="0"/> </extension> <url value="http://terminology.hl7.org/ValueSet/v2-0472"/> <version value="2.9"/> <name value="v2.0472"/> <title value="v2 TQ Conjunction ID"/> <status value="active"/> <experimental value="false"/> <publisher value="HL7, Inc"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org"/> </telecom> </contact> <description value="FHIR Value set/code system definition for HL7 v2 table 0472 ( TQ Conjunction ID)"/> <immutable value="true"/> <compose> <include> <system value="http://terminology.hl7.org/CodeSystem/v2-0472"/> </include> </compose> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.