Release 5 Preview #1

This page is part of the FHIR Specification (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Procedure-example-implant.xml

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Example of a device manipulation (id = "example-implant")

<?xml version="1.0" encoding="UTF-8"?>

<Procedure xmlns="http://hl7.org/fhir">
  <id value="example-implant"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example-implant</p> <p> <b> contained</b> : </p> <p> <b> status</b> : completed</p> <p> <b> code</b> : Implant Pacemaker <span> (Details : {SNOMED CT code '25267002' = 'Insertion of intracardiac pacemaker', given as
           'Insertion of intracardiac pacemaker (procedure)'})</span> </p> <p> <b> subject</b> : <a> Patient/example</a> </p> <p> <b> occurrence</b> : 2015-04-05</p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a> Dr Cecil Surgeon</a> </td> </tr> </table> <p> <b> reason</b> : </p> <p> <b> followUp</b> : ROS 5 days  - 2013-04-10 <span> (Details )</span> </p> <p> <b> note</b> : Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p> <h3> FocalDevices</h3> <table> <tr> <td> -</td> <td> <b> Action</b> </td> <td> <b> Manipulated</b> </td> </tr> <tr> <td> *</td> <td> Implanted <span> (Details : {http://hl7.org/fhir/device-action code 'implanted' = 'Implanted)</span> </td> <td> id: example-pacemaker; manufacturer: Acme Devices, Inc; lotNumber: 1234-5678; Cardiac
             pacemaker implant <span> (Details : {SNOMED CT code '14106009' = 'Cardiac pacemaker', given as 'Cardiac pacemaker
               implant'})</span> </td> </tr> </table> </div> </text> <contained> 
  <Device> 
    <id value="example-pacemaker"/> 
    <manufacturer value="Acme Devices, Inc"/>  
    <lotNumber value="1234-5678"/>  
    <type>  
      <coding>  
        <system value="http://snomed.info/sct"/>  
        <code value="14106009"/>  
        <display value="Cardiac pacemaker implant"/>  
      </coding>  
    </type>  
    <patient>  
      <reference value="Patient/example"/>  
    </patient>  
  </Device> 
  </contained> 
  <status value="completed"/> 
  <code> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="25267002"/> 
      <display value="Insertion of intracardiac pacemaker (procedure)"/> 
    </coding> 
    <text value="Implant Pacemaker"/> 
  </code> 
  <subject> 
    <reference value="Patient/example"/> 
  </subject> 
  <occurrenceDateTime value="2015-04-05"/> 
  <performer> 
    <actor> 
      <reference value="Practitioner/example"/> 
      <display value="Dr Cecil Surgeon"/> 
    </actor> 
  </performer> 
  <reason> 
       <concept> 
       <text value="Bradycardia"/> 
       </concept> 
  </reason> 
  <followUp> 
      <text value="ROS 5 days  - 2013-04-10"/> 
  </followUp> 
  <note>  <text value="Routine Appendectomy. Appendix was inflamed and in retro-caecal position"/> 
  </note> 
  <focalDevice> 
    <action> 
      <coding> 
        <system value="http://hl7.org/fhir/device-action"/> 
        <code value="implanted"/> 
      </coding> 
    </action> 
    <manipulated> 
      <reference value="#example-pacemaker"/> 
    </manipulated> 
  </focalDevice> 
</Procedure> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.