  "resourceType": "Procedure",
  "id": "example-implant",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-implant</p><p><b>contained</b>: </p><p><b>status</b>: completed</p><p><b>code</b>: Implant Pacemaker <span>(Details : {SNOMED CT code '25267002' = 'Insertion of intracardiac pacemaker', given as 'Insertion of intracardiac pacemaker (procedure)'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>occurrence</b>: 2015-04-05</p><h3>Performers</h3><table><tr><td>-</td><td><b>Actor</b></td></tr><tr><td>*</td><td><a>Dr Cecil Surgeon</a></td></tr></table><p><b>reason</b>: </p><p><b>followUp</b>: ROS 5 days  - 2013-04-10 <span>(Details )</span></p><p><b>note</b>: Routine Appendectomy. Appendix was inflamed and in retro-caecal position</p><h3>FocalDevices</h3><table><tr><td>-</td><td><b>Action</b></td><td><b>Manipulated</b></td></tr><tr><td>*</td><td>Implanted <span>(Details : {http://hl7.org/fhir/device-action code 'implanted' = 'Implanted)</span></td><td>id: example-pacemaker; manufacturer: Acme Devices, Inc; lotNumber: 1234-5678; Cardiac pacemaker implant <span>(Details : {SNOMED CT code '14106009' = 'Cardiac pacemaker', given as 'Cardiac pacemaker implant'})</span></td></tr></table></div>"
  },
  "contained": [
    {
      "resourceType": "Device",
      "id": "example-pacemaker",
      "manufacturer": "Acme Devices, Inc",
      "lotNumber": "1234-5678",
      "type": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "14106009",
            "display": "Cardiac pacemaker implant"
          }
        ]
      },
      "patient": {
        "reference": "Patient/example"
      }
    }
  ],
  "status": "completed",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "25267002",
        "display": "Insertion of intracardiac pacemaker (procedure)"
      }
    ],
    "text": "Implant Pacemaker"
  },
  "subject": {
    "reference": "Patient/example"
  },
  "occurrenceDateTime": "2015-04-05",
  "performer": [
    {
      "actor": {
        "reference": "Practitioner/example",
        "display": "Dr Cecil Surgeon"
      }
    }
  ],
  "reason": [
    {
      "concept": {
        "text": "Bradycardia"
      }
    }
  ],
  "followUp": [
    {
      "text": "ROS 5 days  - 2013-04-10"
    }
  ],
  "note": [
    {
      "text": "Routine Appendectomy. Appendix was inflamed and in retro-caecal position"
    }
  ],
  "focalDevice": [
    {
      "action": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/device-action",
            "code": "implanted"
          }
        ]
      },
      "manipulated": {
        "reference": "#example-pacemaker"
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.