Release 5 Preview #1

This page is part of the FHIR Specification (v4.2.0: R5 Preview #1). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Procedure-example-f001-heart.json

Patient Care Work GroupMaturity Level: N/AStandards Status: InformativeCompartments: Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Real-world procedure example

{
  "resourceType": "Procedure",
  "id": "f001",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f001</p><p><b>status</b>: completed</p><p><b>code</b>: Heart valve replacement <span>(Details : {SNOMED CT code '34068001' = 'Heart valve replacement', given as 'Heart valve replacement'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>encounter</b>: <a>Encounter/f001</a></p><p><b>occurrence</b>: 2011-06-26 --&gt; 2011-06-27</p><h3>Performers</h3><table><tr><td>-</td><td><b>Function</b></td><td><b>Actor</b></td></tr><tr><td>*</td><td>Care role <span>(Details : {urn:oid:2.16.840.1.113883.2.4.15.111 code '01.000' = '01.000', given as 'Arts'})</span></td><td><a>P. Voigt</a></td></tr></table><p><b>reason</b>: </p><p><b>bodySite</b>: Heart valve structure <span>(Details : {SNOMED CT code '17401000' = 'Cardiac valve', given as 'Heart valve structure'})</span></p><p><b>outcome</b>: improved blood circulation <span>(Details )</span></p><p><b>report</b>: <a>Lab results blood test</a></p><p><b>followUp</b>: described in care plan <span>(Details )</span></p></div>"
  },
  "status": "completed",
  "code": {
    "coding": [
      {
        "system": "http://snomed.info/sct",
        "code": "34068001",
        "display": "Heart valve replacement"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f001",
    "display": "P. van de Heuvel"
  },
  "encounter": {
    "reference": "Encounter/f001"
  },
  "occurrencePeriod": {
    "start": "2011-06-26",
    "end": "2011-06-27"
  },
  "performer": [
    {
      "function": {
        "coding": [
          {
            "system": "urn:oid:2.16.840.1.113883.2.4.15.111",
            "code": "01.000",
            "display": "Arts"
          }
        ],
        "text": "Care role"
      },
      "actor": {
        "reference": "Practitioner/f002",
        "display": "P. Voigt"
      }
    }
  ],
  "reason": [
    {
      "concept": {
        "text": "Heart valve disorder"
      }
    }
  ],
  "bodySite": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "17401000",
          "display": "Heart valve structure"
        }
      ]
    }
  ],
  "outcome": {
    "text": "improved blood circulation"
  },
  "report": [
    {
      "reference": "DiagnosticReport/f001",
      "display": "Lab results blood test"
    }
  ],
  "followUp": [
    {
      "text": "described in care plan"
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.