FHIR Value set/code system definition for HL7 v2 table 0376 ( Special handling considerations)
{
"resourceType" : "CodeSystem",
"id" : "v2-0376",
"meta" : {
"profile" : ["http://hl7.org/fhir/StructureDefinition/shareablecodesystem"]
},
"language" : "en",
"text" : {
"status" : "additional",
"div" : "<div>!-- Snipped for Brevity --></div>"
},
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status",
"valueString" : "External"
},
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm",
"valueInteger" : 0
}],
"url" : "http://terminology.hl7.org/CodeSystem/v2-0376",
"identifier" : [{
"system" : "urn:ietf:rfc:3986",
"value" : "urn:oid:2.16.840.1.113883.18.234"
}],
"version" : "2.9",
"name" : "v2.0376",
"title" : "v2 Special handling considerations",
"status" : "active",
"experimental" : false,
"publisher" : "HL7, Inc",
"contact" : [{
"telecom" : [{
"system" : "url",
"value" : "http://hl7.org"
}]
}],
"description" : "FHIR Value set/code system definition for HL7 v2 table 0376 ( Special handling considerations)",
"content" : "complete",
"concept" : [{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Keep at ambient (room) temperature, approximately 22 ( 2 degrees C. Accidental refrigeration or freezing is of little consequence"
}],
"code" : "AMB",
"display" : "Ambient temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Critical to keep at body temperature: 36 - 38( C."
}],
"code" : "C37",
"display" : "Body temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Critical ambient - must not be refrigerated or frozen."
}],
"code" : "CAMB",
"display" : "Critical ambient temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Critical. Do not expose to atmosphere. Do not uncap."
}],
"code" : "CATM",
"display" : "Protect from air"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Critical frozen - must not be allowed to thaw until immediately prior to testing"
}],
"code" : "CFRZ",
"display" : "Critical frozen temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Critical refrigerated - must not be allowed to freeze or warm until immediately prior to testing"
}],
"code" : "CREF",
"display" : "Critical refrigerated temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Deep frozen: -16 to -20( C."
}],
"code" : "DFRZ",
"display" : "Deep frozen"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Keep in a dry environment."
}],
"code" : "DRY",
"display" : "Dry"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Keep at frozen temperature: -4( C. Accidental thawing is of little consequence"
}],
"code" : "FRZ",
"display" : "Frozen temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Container is free of heavy metals including lead."
}],
"code" : "MTLF",
"display" : "Metal Free"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Keep in liquid nitrogen."
}],
"code" : "NTR",
"display" : "Liquid nitrogen"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Protect from light (e.g., wrap in aluminum foil)."
}],
"code" : "PRTL",
"display" : "Protect from light"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Do not shake."
}],
"code" : "PSA",
"display" : "Do not shake"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Protect from shock."
}],
"code" : "PSO",
"display" : "No shock"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Keep at refrigerated temperature: 4-8( C. Accidental warming or freezing is of little consequence"
}],
"code" : "REF",
"display" : "Refrigerated temperature"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Ultra cold frozen: ~ -75 to -85( C. (ultra cold freezer is typically at temperature of dry ice)."
}],
"code" : "UFRZ",
"display" : "Ultra frozen"
},
{
"extension" : [{
"url" : "http://hl7.org/fhir/StructureDefinition/codesystem-comments",
"valueString" : "Keep upright. Do not turn upside down."
}],
"code" : "UPR",
"display" : "Upright"
}]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.