R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Specimen-example.xml

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Patient, Practitioner

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

General Specimen Example (id = "101")

<?xml version="1.0" encoding="UTF-8"?>

<Specimen xmlns="http://hl7.org/fhir">
  <id value="101"/> 
  <!--   text>
    <status value="generated" />
    <div xmlns="http://www.w3.org/1999/xhtml">[Put rendering here]</div>
  </text>   -->
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : 101</p> <p> <b> contained</b> : </p> <p> <b> identifier</b> : 23234352356</p> <p> <b> accessionIdentifier</b> : X352356</p> <p> <b> status</b> : available</p> <p> <b> type</b> : Venous blood specimen <span> (Details : {SNOMED CT code '122555007' = 'Venous blood specimen', given as 'Venous blood
           specimen'})</span> </p> <p> <b> subject</b> : <a> Peter Patient</a> </p> <p> <b> receivedTime</b> : 04/03/2011 7:03:00 AM</p> <p> <b> request</b> : <a> ServiceRequest/example</a> </p> <h3> Collections</h3> <table> <tr> <td> -</td> <td> <b> Collector</b> </td> <td> <b> Collected[x]</b> </td> <td> <b> Quantity</b> </td> <td> <b> Method</b> </td> <td> <b> BodySite</b> </td> </tr> <tr> <td> *</td> <td> <a> Practitioner/example</a> </td> <td> 30/05/2011 6:15:00 AM</td> <td> 6 mL</td> <td> Line, Venous <span> (Details : {http://terminology.hl7.org/CodeSystem/v2-0488 code 'LNV' = 'Line, Venous)</span> </td> <td> Right median cubital vein <span> (Details : {SNOMED CT code '49852007' = 'Median cubital vein', given as 'Structure of
               median cubital vein (body structure)'})</span> </td> </tr> </table> <h3> Containers</h3> <table> <tr> <td> -</td> <td> <b> Identifier</b> </td> <td> <b> Description</b> </td> <td> <b> Type</b> </td> <td> <b> Capacity</b> </td> <td> <b> SpecimenQuantity</b> </td> <td> <b> Additive[x]</b> </td> </tr> <tr> <td> *</td> <td> 48736-15394-75465</td> <td> Green Gel tube</td> <td> Vacutainer <span> (Details )</span> </td> <td> 10 mL</td> <td> 6 mL</td> <td> id: hep; Lithium/Li Heparin <span> (Details : {http://terminology.hl7.org/CodeSystem/v3-EntityCode code 'HEPL' = 'Lithium/Li
               Heparin)</span> </td> </tr> </table> <p> <b> note</b> : Specimen is grossly lipemic</p> </div> </text> <contained> 
    <Substance> 
      <id value="hep"/> 
      <code> 
        <coding> 
          <system value="http://terminology.hl7.org/CodeSystem/v3-EntityCode"/> 
          <code value="HEPL"/> 
        </coding> 
      </code> 
    </Substance> 
  </contained> 
  <identifier> 
    <!--    a specimen identifier - e.g. assigned when the specimen was taken this is often not
     done    -->
    <system value="http://ehr.acme.org/identifiers/collections"/> 
    <value value="23234352356"/> 
  </identifier> 
  <accessionIdentifier> 
    <system value="http://lab.acme.org/specimens/2011"/> 
    <value value="X352356"/> 
  </accessionIdentifier> 
  <status value="available"/> 
  <type> 
    <!--   
   Type is a loosely defined field because there is such a lot of variation in how it
     is used.
   The principal variation is how much information that could be represented elsewhere
     is also
   represented here. For instance, here's some possible types:
     lithium heparin plasma   (+ .container.additive) (e.g. SNOMED CT 446272009)
     transfusion bag of blood (+ container.type)
     Peritoneal lavage        (+ collection.bodySite)
   If the type includes other fields, it would be normal not to populate the other fields

   Note that this practice is so widespread that it's pointless to try and stop it    -->
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="122555007"/> 
      <display value="Venous blood specimen"/> 
    </coding> 
  </type> 
  <subject> 
    <reference value="Patient/example"/> 
    <display value="Peter Patient"/> 
  </subject> 
  <receivedTime value="2011-03-04T07:03:00Z"/> 
  <request> 
    <!--    this points to the order that caused the sample to be drawn    -->
    <reference value="ServiceRequest/example"/> 
  </request> 
  <collection> 
    <collector> 
      <!--    in practice, collecter is almost always recorded    -->
      <reference value="Practitioner/example"/> 
    </collector> 
    <!--    the time of collection is usually required. Usually a point in time, but can be a period
      (collectedPeriod) if it's a timed collection (e.g. a 24 hour urine)    -->
    <collectedDateTime value="2011-05-30T06:15:00Z"/> 
    <quantity> 
      <value value="6"/> 
      <unit value="mL"/> 
      <!--    e.g. full    -->
    </quantity> 
    <!--    method is usually implied by type    -->
    <method> 
      <coding> 
        <system value="http://terminology.hl7.org/CodeSystem/v2-0488"/> 
        <code value="LNV"/> 
      </coding> 
    </method> 
    <!--    bodysite is usually implied by type too its here to demonstrate its usage to indicating
     the draw site in this case   -->
    <bodySite> 
      <coding> 
        <system value="http://snomed.info/sct"/> 
        <code value="49852007"/> 
        <display value="Structure of median cubital vein (body structure)"/> 
      </coding> 
      <text value="Right median cubital vein"/> 
    </bodySite> 
  </collection> 
  <!--   
      the container identifier is not the same as the specimen identifier
      usually, it is pre-printed/implanted etc.on the container prior to
      use. It might a RFID in the container, or it might be a UDI
      (http://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/UniqueDeviceIdentification/)
       -->
    <container> 
  <identifier> 
    <!--    this is a serial number off the tube - there's no context such as a system    -->
    <value value="48736-15394-75465"/> 
  </identifier> 
  <description value="Green Gel tube"/> 
  <type> 
    <!--    again, this might easily be used to cover additives and capacity as well    -->
    <text value="Vacutainer"/> 
  </type> 
  <capacity> 
    <value value="10"/> 
    <unit value="mL"/> 
  </capacity> 
  <!--    if there's only one container, then this value is the same
     as .collection.quantity (usually). This is for when there is more
     than one container    -->
  <specimenQuantity> 
    <value value="6"/> 
    <unit value="mL"/> 
  </specimenQuantity> 
  <additiveReference> 
    <reference value="#hep"/> 
  </additiveReference> 
  </container> 
  <note> 
    <text value="Specimen is grossly lipemic"/> 
  </note> 
</Specimen> 