This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Patient Care Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Encounter, Patient, Practitioner, RelatedPerson |
Raw JSON (canonical form + also see JSON Format Specification)
Real-world procedure example
{ "resourceType": "Procedure", "id": "f001", "text": { "status": "generated", "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f001</p><p><b>status</b>: completed</p><p><b>code</b>: Heart valve replacement <span>(Details : {SNOMED CT code '34068001' = 'Heart valve replacement', given as 'Heart valve replacement'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>context</b>: <a>Encounter/f001</a></p><p><b>performed</b>: 26/06/2011 --> 27/06/2011</p><h3>Performers</h3><table><tr><td>-</td><td><b>Function</b></td><td><b>Actor</b></td></tr><tr><td>*</td><td>Care role <span>(Details : {urn:oid:2.16.840.1.113883.2.4.15.111 code '01.000' = '01.000', given as 'Arts'})</span></td><td><a>P. Voigt</a></td></tr></table><p><b>reasonCode</b>: Heart valve disorder <span>(Details )</span></p><p><b>bodySite</b>: Heart valve structure <span>(Details : {SNOMED CT code '17401000' = 'Cardiac valve', given as 'Heart valve structure'})</span></p><p><b>outcome</b>: improved blood circulation <span>(Details )</span></p><p><b>report</b>: <a>Lab results blood test</a></p><p><b>followUp</b>: described in care plan <span>(Details )</span></p></div>" }, "status": "completed", "code": { "coding": [ { "system": "http://snomed.info/sct", "code": "34068001", "display": "Heart valve replacement" } ] }, "subject": { "reference": "Patient/f001", "display": "P. van de Heuvel" }, "context": { "reference": "Encounter/f001" }, "performedPeriod": { "start": "2011-06-26", "end": "2011-06-27" }, "performer": [ { "function": { "coding": [ { "system": "urn:oid:2.16.840.1.113883.2.4.15.111", "code": "01.000", "display": "Arts" } ], "text": "Care role" }, "actor": { "reference": "Practitioner/f002", "display": "P. Voigt" } } ], "reasonCode": [ { "text": "Heart valve disorder" } ], "bodySite": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "17401000", "display": "Heart valve structure" } ] } ], "outcome": { "text": "improved blood circulation" }, "report": [ { "reference": "DiagnosticReport/f001", "display": "Lab results blood test" } ], "followUp": [ { "text": "described in care plan" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.