R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-f003-co2.json

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw JSON (canonical form + also see JSON Format Specification)

Real-world patient - CO2

{
  "resourceType": "Observation",
  "id": "f003",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f003</p><p><b>identifier</b>: 6325 (OFFICIAL)</p><p><b>status</b>: final</p><p><b>code</b>: Carbon dioxide in blood <span>(Details : {LOINC code '11557-6' = 'Carbon dioxide [Partial pressure] in Blood', given as 'Carbon dioxide in blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 10:30:10 AM --&gt; 05/04/2013 10:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>value</b>: 6.2 kPa<span> (Details: UCUM code kPa = 'kPa')</span></p><p><b>interpretation</b>: High <span>(Details : {http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation code 'H' = 'High', given as 'High'})</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>4.8 kPa<span> (Details: UCUM code kPa = 'kPa')</span></td><td>6.0 kPa<span> (Details: UCUM code kPa = 'kPa')</span></td></tr></table></div>"
  },
  "identifier": [
    {
      "use": "official",
      "system": "http://www.bmc.nl/zorgportal/identifiers/observations",
      "value": "6325"
    }
  ],
  "status": "final",
  "code": {
    "coding": [
      {
        "system": "http://loinc.org",
        "code": "11557-6",
        "display": "Carbon dioxide in blood"
      }
    ]
  },
  "subject": {
    "reference": "Patient/f001",
    "display": "P. van de Heuvel"
  },
  "effectivePeriod": {
    "start": "2013-04-02T10:30:10+01:00",
    "end": "2013-04-05T10:30:10+01:00"
  },
  "issued": "2013-04-03T15:30:10+01:00",
  "performer": [
    {
      "reference": "Practitioner/f005",
      "display": "A. Langeveld"
    }
  ],
  "valueQuantity": {
    "value": 6.2,
    "unit": "kPa",
    "system": "http://unitsofmeasure.org",
    "code": "kPa"
  },
  "interpretation": [
    {
      "coding": [
        {
          "system": "http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation",
          "code": "H",
          "display": "High"
        }
      ]
    }
  ],
  "referenceRange": [
    {
      "low": {
        "value": 4.8,
        "unit": "kPa",
        "system": "http://unitsofmeasure.org",
        "code": "kPa"
      },
      "high": {
        "value": 6.0,
        "unit": "kPa",
        "system": "http://unitsofmeasure.org",
        "code": "kPa"
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.