This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Infrastructure And Messaging Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Practitioner |
Raw Turtle (+ also see Turtle/RDF Format Specification)
A typical message header
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/MessageHeader/1cbdfb97-5859-48a4-8301-d54eab818d68> a fhir:MessageHeader; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "1cbdfb97-5859-48a4-8301-d54eab818d68"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <p>Update Person resource for Peter James CHALMERS (Jim), MRN: 12345 (Acme Healthcare)</p>\n </div>" ]; fhir:MessageHeader.eventCoding [ fhir:Coding.system [ fhir:value "http://example.org/fhir/message-events" ]; fhir:Coding.code [ fhir:value "admin-notify" ] ]; fhir:MessageHeader.destination [ fhir:index 0; fhir:MessageHeader.destination.name [ fhir:value "Acme Message Gateway" ]; fhir:MessageHeader.destination.target [ fhir:link <http://hl7.org/fhir/Device/example>; fhir:Reference.reference [ fhir:value "Device/example" ] ]; fhir:MessageHeader.destination.endpoint [ fhir:value "llp:10.11.12.14:5432" ]; fhir:MessageHeader.destination.receiver [ fhir:link <http://acme.com/ehr/fhir/Practitioner/2323-33-4>; fhir:Reference.reference [ fhir:value "http://acme.com/ehr/fhir/Practitioner/2323-33-4" ] ] ]; fhir:MessageHeader.sender [ fhir:link <http://hl7.org/fhir/Organization/1>; fhir:Reference.reference [ fhir:value "Organization/1" ] ]; fhir:MessageHeader.enterer [ fhir:link <http://hl7.org/fhir/Practitioner/example>; fhir:Reference.reference [ fhir:value "Practitioner/example" ] ]; fhir:MessageHeader.author [ fhir:link <http://hl7.org/fhir/Practitioner/example>; fhir:Reference.reference [ fhir:value "Practitioner/example" ] ]; fhir:MessageHeader.source [ fhir:MessageHeader.source.name [ fhir:value "Acme Central Patient Registry" ]; fhir:MessageHeader.source.software [ fhir:value "FooBar Patient Manager" ]; fhir:MessageHeader.source.version [ fhir:value "3.1.45.AABB" ]; fhir:MessageHeader.source.contact [ fhir:ContactPoint.system [ fhir:value "phone" ]; fhir:ContactPoint.value [ fhir:value "+1 (555) 123 4567" ] ]; fhir:MessageHeader.source.endpoint [ fhir:value "llp:10.11.12.13:5432" ] ]; fhir:MessageHeader.reason [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/message-reasons-encounter" ]; fhir:Coding.code [ fhir:value "admit" ] ] ]; fhir:MessageHeader.response [ fhir:MessageHeader.response.identifier [ fhir:value "5015fe84-8e76-4526-89d8-44b322e8d4fb" ]; fhir:MessageHeader.response.code [ fhir:value "ok" ] ]; fhir:MessageHeader.focus [ fhir:index 0; fhir:link <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ]; fhir:MessageHeader.definition [ fhir:value "http:////acme.com/ehr/fhir/messagedefinition/patientrequest"; fhir:link <http:////acme.com/ehr/fhir/messagedefinition/patientrequest> ] . <http://hl7.org/fhir/Device/example> a fhir:Device . <http://hl7.org/fhir/Organization/1> a fhir:Organization . <http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner . <http://hl7.org/fhir/Patient/example> a fhir:Patient . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/MessageHeader/1cbdfb97-5859-48a4-8301-d54eab818d68.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/MessageHeader/1cbdfb97-5859-48a4-8301-d54eab818d68.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.