This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Pharmacy Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Patient, Practitioner, RelatedPerson |
Raw XML (canonical form + also see XML Format Specification)
Patient reports they were taking Amoxycillin in the past but are not taking it now (id = "example004")
<?xml version="1.0" encoding="UTF-8"?> <MedicationStatement xmlns="http://hl7.org/fhir"> <id value="example004"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example004</p> <p> <b> partOf</b> : <a> Observation/blood-pressure</a> </p> <p> <b> status</b> : completed</p> <p> <b> medication</b> : Amoxicillin (product) <span> (Details : {SNOMED CT code '27658006' = 'p-Hydroxyampicillin', given as 'Amoxicillin (product)'})</span> </p> <p> <b> subject</b> : <a> Donald Duck</a> </p> <p> <b> effective</b> : 23/01/2014</p> <p> <b> dateAsserted</b> : 22/02/2015</p> <p> <b> informationSource</b> : <a> Donald Duck</a> </p> <p> <b> reasonCode</b> : Otitis Media <span> (Details : {SNOMED CT code '65363002' = 'Otitis media', given as 'Otitis Media'})</span> </p> <p> <b> note</b> : Patient indicates they miss the occasional dose</p> <p> <b> dosage</b> : </p> </div> </text> <partOf> <reference value="Observation/blood-pressure"/> </partOf> <status value="completed"/> <medicationCodeableConcept> <coding> <system value="http://snomed.info/sct"/> <code value="27658006"/> <display value="Amoxicillin (product)"/> </coding> </medicationCodeableConcept> <subject> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> <effectiveDateTime value="2014-01-23"/> <dateAsserted value="2015-02-22"/> <informationSource> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </informationSource> <reasonCode> <coding> <system value="http://snomed.info/sct"/> <code value="65363002"/> <display value="Otitis Media"/> </coding> </reasonCode> <note> <text value="Patient indicates they miss the occasional dose"/> </note> <dosage> <text value="one capsule three times daily"/> <timing> <repeat> <frequency value="3"/> <period value="1"/> <periodUnit value="d"/> </repeat> </timing> <asNeededBoolean value="false"/> <route> <coding> <system value="http://snomed.info/sct"/> <code value="260548002"/> <display value="Oral"/> </coding> </route> <maxDosePerPeriod> <numerator> <value value="3"/> <unit value="capsules"/> <system value="http://snomed.info/sct"/> <code value="385055001"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </denominator> </maxDosePerPeriod> </dosage> </MedicationStatement>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.