This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4
Pharmacy Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Encounter, Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Request for Intravenous Dopamine - Weight based calculation with rateQuantity (id = "medrx0336")
<?xml version="1.0" encoding="UTF-8"?> <MedicationRequest xmlns="http://hl7.org/fhir"> <id value="medrx0336"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : medrx0336</p> <p> <b> contained</b> : </p> <p> <b> identifier</b> : 12345689 (OFFICIAL)</p> <p> <b> status</b> : completed</p> <p> <b> intent</b> : order</p> <p> <b> medication</b> : Dopamine 400mg in 500mL D5W. Generated Summary: id: med0336; Injection Solution (qualifier value) <span> (Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection Solution (qualifier value)'})</span> </p> <p> <b> subject</b> : <a> Donald Duck</a> </p> <p> <b> supportingInformation</b> : <a> Observation/example</a> </p> <p> <b> authoredOn</b> : 15/01/2015</p> <p> <b> requester</b> : <a> Patrick Pump</a> </p> <p> <b> dosageInstruction</b> : </p> </div> </text> <contained> <Medication> <id value="med0336"/> <form> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection Solution (qualifier value)"/> </coding> <text value="Injection Solution (qualifier value)"/> </form> <ingredient> <itemCodeableConcept> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="1114879"/> <display value="Dopamine"/> </coding> </itemCodeableConcept> <amount> <numerator> <value value="400"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </numerator> <denominator> <value value="500"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </amount> </ingredient> <ingredient> <itemCodeableConcept> <coding> <system value="http://hl7.org/fhir/sid/ndc"/> <code value="0264751010"/> <display value="Dextrose 5% injection USP"/> </coding> </itemCodeableConcept> <amount> <numerator> <value value="5"/> <system value="http://unitsofmeasure.org"/> <code value="g"/> </numerator> <denominator> <value value="100"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </amount> </ingredient> </Medication> </contained> <identifier> <use value="official"/> <system value="http://www.bmc.nl/portal/prescriptions"/> <value value="12345689"/> </identifier> <status value="completed"/> <intent value="order"> </intent> <medicationReference> <!-- Linked to a RESOURCE Medication --> <reference value="#med0336"/> <display value="Dopamine 400mg in 500mL D5W"/> </medicationReference> <subject> <!-- Linked to the resource patient who needs the medication --> <reference value="Patient/pat1"/> <display value="Donald Duck"/> </subject> <supportingInformation> <reference value="Observation/example"/> </supportingInformation> <authoredOn value="2015-01-15"/> <requester> <reference value="Practitioner/f007"/> <display value="Patrick Pump"/> </requester> <dosageInstruction> <sequence value="1"/> <text value="Dopamine 4mcg/kg/min"/> <timing> <repeat> <duration value="33.33"/> <durationUnit value="h"/> </repeat> </timing> <route> <coding> <system value="http://snomed.info/sct"/> <code value="47625008"/> <display value="Intravenous route (qualifier value)"/> </coding> </route> <doseAndRate> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/dose-rate-type"/> <code value="ordered"/> <display value="Ordered"/> </coding> </type> <rateQuantity> <value value="4"/> <unit value="ug/kg/min"/> <system value="http://unitsofmeasure.org"/> </rateQuantity> </doseAndRate> </dosageInstruction> </MedicationRequest>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.