R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationrequest0315.ttl

Pharmacy Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Encounter, Patient, Practitioner

Raw Turtle (+ also see Turtle/RDF Format Specification)

Request for an injectable medication - Lorazepam - active - with link to encounter, reasonCode and dosageInstruction

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/MedicationRequest/medrx0315> a fhir:MedicationRequest;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "medrx0315"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medrx0315</p><p><b>contained</b>: </p><p><b>identifier</b>: 12345689 (OFFICIAL)</p><p><b>status</b>: active</p><p><b>intent</b>: order</p><p><b>medication</b>: id: med0313; Lorazepam 2mg/ml injection solution 1ml vial (product) <span>(Details : {SNOMED CT code '400621001' = 'Lorazepam 2mg/mL injection solution 1mL vial', given as 'Lorazepam 2mg/ml injection solution 1ml vial (product)'})</span>; Injection solution (qualifier value) <span>(Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection solution (qualifier value)'})</span></p><p><b>subject</b>: <a>Donald Duck</a></p><p><b>context</b>: <a>encounter who leads to this prescription</a></p><p><b>authoredOn</b>: 15/01/2015</p><p><b>requester</b>: <a>Patrick Pump</a></p><p><b>reasonCode</b>: Epilepsy (disorder) <span>(Details : {SNOMED CT code '84757009' = 'Epilepsy', given as 'Epilepsy (disorder)'})</span></p><p><b>dosageInstruction</b>: </p></div>"
  ];
  fhir:DomainResource.contained [
     a fhir:Medication;
     fhir:index 0;
     fhir:Resource.id [ fhir:value "med0313" ];
     fhir:Medication.code [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:400621001;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "400621001" ];
         fhir:Coding.display [ fhir:value "Lorazepam 2mg/ml injection solution 1ml vial (product)" ]
       ]
     ];
     fhir:Medication.form [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:385219001;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "385219001" ];
         fhir:Coding.display [ fhir:value "Injection solution (qualifier value)" ]
       ]
     ];
     fhir:Medication.ingredient [
       fhir:index 0;
       fhir:Medication.ingredient.itemCodeableConcept [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           a sct:387106007;
           fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
           fhir:Coding.code [ fhir:value "387106007" ];
           fhir:Coding.display [ fhir:value "Lorazepam (substance)" ]
         ]
       ];
       fhir:Medication.ingredient.amount [
         fhir:Ratio.numerator [
           fhir:Quantity.value [ fhir:value "2"^^xsd:decimal ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "mg" ]
         ];
         fhir:Ratio.denominator [
           fhir:Quantity.value [ fhir:value "1"^^xsd:decimal ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "mL" ]
         ]
       ]
     ]
  ];
  fhir:MedicationRequest.identifier [
     fhir:index 0;
     fhir:Identifier.use [ fhir:value "official" ];
     fhir:Identifier.system [ fhir:value "http://www.bmc.nl/portal/prescriptions" ];
     fhir:Identifier.value [ fhir:value "12345689" ]
  ];
  fhir:MedicationRequest.status [ fhir:value "active"];
  fhir:MedicationRequest.intent [ fhir:value "order"];
  fhir:MedicationRequest.medicationReference [
     fhir:Reference.reference [ fhir:value "#med0313" ]
  ];
  fhir:MedicationRequest.subject [
     fhir:link <http://hl7.org/fhir/Patient/pat1>;
     fhir:Reference.reference [ fhir:value "Patient/pat1" ];
     fhir:Reference.display [ fhir:value "Donald Duck" ]
  ];
  fhir:MedicationRequest.context [
     fhir:link <http://hl7.org/fhir/Encounter/f001>;
     fhir:Reference.reference [ fhir:value "Encounter/f001" ];
     fhir:Reference.display [ fhir:value "encounter who leads to this prescription" ]
  ];
  fhir:MedicationRequest.authoredOn [ fhir:value "2015-01-15"^^xsd:date];
  fhir:MedicationRequest.requester [
     fhir:link <http://hl7.org/fhir/Practitioner/f007>;
     fhir:Reference.reference [ fhir:value "Practitioner/f007" ];
     fhir:Reference.display [ fhir:value "Patrick Pump" ]
  ];
  fhir:MedicationRequest.reasonCode [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:84757009;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "84757009" ];
       fhir:Coding.display [ fhir:value "Epilepsy (disorder)" ]
     ]
  ];
  fhir:MedicationRequest.dosageInstruction [
     fhir:index 0;
     fhir:Dosage.sequence [ fhir:value "1"^^xsd:integer ];
     fhir:Dosage.text [ fhir:value "0.05 - 0.1mg/kg IV over 2-5 minutes every 15 minutes as needed" ];
     fhir:Dosage.timing [
       fhir:Timing.repeat [
         fhir:Timing.repeat.frequency [ fhir:value "1"^^xsd:positiveInteger ];
         fhir:Timing.repeat.period [ fhir:value "15"^^xsd:decimal ];
         fhir:Timing.repeat.periodUnit [ fhir:value "min" ]
       ]
     ];
     fhir:Dosage.asNeededBoolean [ fhir:value "true"^^xsd:boolean ];
     fhir:Dosage.route [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:255560000;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "255560000" ];
         fhir:Coding.display [ fhir:value "Intravenous" ]
       ]
     ];
     fhir:Dosage.method [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:420620005;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "420620005" ];
         fhir:Coding.display [ fhir:value "Push - dosing instruction imperative (qualifier value)" ]
       ]
     ];
     fhir:Dosage.doseAndRate [
       fhir:index 0;
       fhir:Dosage.doseAndRate.type [
         fhir:CodeableConcept.coding [
           fhir:index 0;
           fhir:Coding.system [ fhir:value "http://terminology.hl7.org/CodeSystem/dose-rate-type" ];
           fhir:Coding.code [ fhir:value "ordered" ];
           fhir:Coding.display [ fhir:value "Ordered" ]
         ]
       ];
       fhir:Dosage.doseAndRate.doseRange [
         fhir:Range.low [
           fhir:Quantity.value [ fhir:value "0.05"^^xsd:decimal ];
           fhir:Quantity.unit [ fhir:value "mg/kg" ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "mg/kg" ]
         ];
         fhir:Range.high [
           fhir:Quantity.value [ fhir:value "0.1"^^xsd:decimal ];
           fhir:Quantity.unit [ fhir:value "mg/kg" ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "mg/kg" ]
         ]
       ];
       fhir:Dosage.doseAndRate.rateRange [
         fhir:Range.low [
           fhir:Quantity.value [ fhir:value "2"^^xsd:decimal ];
           fhir:Quantity.unit [ fhir:value "min" ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "min" ]
         ];
         fhir:Range.high [
           fhir:Quantity.value [ fhir:value "5"^^xsd:decimal ];
           fhir:Quantity.unit [ fhir:value "min" ];
           fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
           fhir:Quantity.code [ fhir:value "min" ]
         ]
       ]
     ]
  ] .

<http://hl7.org/fhir/Patient/pat1> a fhir:Patient .

<http://hl7.org/fhir/Encounter/f001> a fhir:Encounter .

<http://hl7.org/fhir/Practitioner/f007> a fhir:Practitioner .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/MedicationRequest/medrx0315.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/MedicationRequest/medrx0315.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.