This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Pharmacy Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Patient, Practitioner |
Raw XML (canonical form + also see XML Format Specification)
Dispense for Lorazepam (Rx norm code) - completed with rate range (id = "meddisp0314")
<?xml version="1.0" encoding="UTF-8"?> <MedicationDispense xmlns="http://hl7.org/fhir"> <id value="meddisp0314"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : meddisp0314</p> <p> <b> contained</b> : </p> <p> <b> status</b> : completed</p> <p> <b> medication</b> : id: med0313; Lorazepam 2mg/ml Injectable Solution (Ativan) <span> (Details : {RxNorm code '206819' = 'Ativan 2 MG/ML Injectable Solution', given as 'Lorazepam 2mg/ml Injectable Solution (Ativan)'})</span> ; Injection solution (qualifier value) <span> (Details : {SNOMED CT code '385219001' = 'Injection solution', given as 'Injection solution (qualifier value)'})</span> </p> <p> <b> subject</b> : <a> Donald Duck </a> </p> <h3> Performers</h3> <table> <tr> <td> -</td> <td> <b> Actor</b> </td> </tr> <tr> <td> *</td> <td> <a> Practitioner/f006</a> </td> </tr> </table> <p> <b> authorizingPrescription</b> : <a> MedicationRequest/medrx0315</a> </p> <p> <b> type</b> : Trial Fill <span> (Details : {http://terminology.hl7.org/CodeSystem/v3-ActCode code 'TF' = 'Trial Fill', given as 'Trial Fill'})</span> </p> <p> <b> quantity</b> : 1 415818005<span> (Details: SNOMED CT code 415818005 = '415818005')</span> </p> <p> <b> daysSupply</b> : 1 Day<span> (Details: UCUM code d = 'd')</span> </p> <p> <b> whenPrepared</b> : 25/06/2015 7:13:00 AM</p> <p> <b> whenHandedOver</b> : 26/06/2015 7:13:00 AM</p> <p> <b> dosageInstruction</b> : </p> </div> </text> <contained> <Medication> <id value="med0313"/> <code> <coding> <system value="http://www.nlm.nih.gov/research/umls/rxnorm"/> <code value="206819"/> <display value="Lorazepam 2mg/ml Injectable Solution (Ativan)"/> </coding> </code> <form> <coding> <system value="http://snomed.info/sct"/> <code value="385219001"/> <display value="Injection solution (qualifier value)"/> </coding> </form> <ingredient> <itemCodeableConcept> <coding> <system value="http://snomed.info/sct"/> <code value="387106007"/> <display value="Lorazepam (substance)"/> </coding> </itemCodeableConcept> <amount> <numerator> <value value="2"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </numerator> <denominator> <value value="1"/> <system value="http://unitsofmeasure.org"/> <code value="mL"/> </denominator> </amount> </ingredient> </Medication> </contained> <status value="completed"/> <medicationReference> <!-- Linked to a RESOURCE Medication --> <reference value="#med0313"/> </medicationReference> <subject> <reference value="Patient/pat1"/> <display value="Donald Duck "/> </subject> <performer> <actor> <reference value="Practitioner/f006"/> </actor> </performer> <authorizingPrescription> <reference value="MedicationRequest/medrx0315"/> </authorizingPrescription> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/v3-ActCode"/> <code value="TF"/> <display value="Trial Fill"/> </coding> </type> <quantity> <value value="1"/> <system value="http://snomed.info/sct"/> <code value="415818005"/> </quantity> <daysSupply> <value value="1"/> <unit value="Day"/> <system value="http://unitsofmeasure.org"/> <code value="d"/> </daysSupply> <whenPrepared value="2015-06-25T07:13:00+05:00"/> <whenHandedOver value="2015-06-26T07:13:00+05:00"/> <dosageInstruction> <sequence value="1"/> <text value="7mg IV over 2-5 minutes every 15 minutes as needed"/> <timing> <repeat> <frequency value="1"/> <period value="15"/> <periodUnit value="min"/> </repeat> </timing> <asNeededBoolean value="true"/> <route> <coding> <system value="http://snomed.info/sct"/> <code value="255560000"/> <display value="Intravenous"/> </coding> </route> <method> <coding> <system value="http://snomed.info/sct"/> <code value="420620005"/> <display value="Push - dosing instruction imperative (qualifier value)"/> </coding> </method> <doseAndRate> <type> <coding> <system value="http://terminology.hl7.org/CodeSystem/dose-rate-type"/> <code value="ordered"/> <display value="Ordered"/> </coding> </type> <doseQuantity> <value value="7"/> <unit value="mg"/> <system value="http://unitsofmeasure.org"/> <code value="mg"/> </doseQuantity> <rateRange> <low> <value value="2"/> <unit value="min"/> <system value="http://unitsofmeasure.org"/> <code value="min"/> </low> <high> <value value="5"/> <unit value="min"/> <system value="http://unitsofmeasure.org"/> <code value="min"/> </high> </rateRange> </doseAndRate> </dosageInstruction> </MedicationDispense>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.