R4 Ballot #2 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Devicerequest-example-insulinpump.xml

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner

Raw XML (canonical form + also see XML Format Specification)

Jump past Narrative

Insulin Pump request (id = "insulinpump")

<?xml version="1.0" encoding="UTF-8"?>

<DeviceRequest xmlns="http://hl7.org/fhir">
  <id value="insulinpump"/> 
  <!--     <extension url="http://hl7.org/fhir/StructureDefinition/bodysitecode">
  <valueCodeableConcept>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="51185008"/>
      <display value="Thoracic structure"/>
    </coding>
  </valueCodeableConcept>
</extension>     -->
<text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : insulinpump</p> <p> <b> identifier</b> : ip_request1.1</p> <p> <b> instantiatesCanonical</b> : <a> http://motivemi.com/artifacts/PlanDefinition/low-suicide-risk-order-set</a> </p> <p> <b> basedOn</b> : Homecare - DM follow-up</p> <p> <b> priorRequest</b> : CGM ambulatory</p> <p> <b> groupIdentifier</b> : ip_request1</p> <p> <b> status</b> : active</p> <p> <b> intent</b> : instance-order</p> <p> <b> priority</b> : routine</p> <p> <b> code</b> : Insulin delivery device panel <span> (Details : {LOINC code '43148-6' = 'Insulin delivery device panel)</span> </p> <p> <b> subject</b> : <a> Patient/dicom</a> </p> <p> <b> context</b> : Encounter 1</p> <p> <b> occurrence</b> : 08/05/2013 9:33:27 AM</p> <p> <b> authoredOn</b> : 08/05/2013 9:33:27 AM</p> <p> <b> requester</b> : <a> Dr. Adam Careful</a> </p> <p> <b> performerType</b> : Nurse <span> (Details : {[not stated] code 'null' = 'null', given as 'Qualified nurse'})</span> </p> <p> <b> performer</b> : Nurse Rossignol</p> <p> <b> reasonCode</b> : gastroparesis <span> (Details )</span> </p> <p> <b> reasonReference</b> : Gastroparesis</p> <p> <b> supportingInfo</b> : Previous results</p> <p> <b> note</b> : this is the right device brand and model</p> <p> <b> relevantHistory</b> : Request for unspecified device</p> </div> </text> <identifier> 
  <value value="ip_request1.1"/> 
</identifier> 
<instantiatesCanonical value="http://motivemi.com/artifacts/PlanDefinition/low-suicide-risk-order-set"/> 
<basedOn> 
  <display value="Homecare - DM follow-up"/> 
</basedOn> 
<priorRequest> 
  <display value="CGM ambulatory"/> 
</priorRequest> 
<groupIdentifier> 
  <value value="ip_request1"/> 
</groupIdentifier> 
<status value="active"/> 
<intent value="instance-order"/> 
<priority value="routine"/> 
<codeCodeableConcept> 
  <coding> 
    <system value="http://loinc.org"/> 
    <code value="43148-6"/> 
  </coding> 
  <text value="Insulin delivery device panel"/> 
</codeCodeableConcept> 
<subject> 
  <reference value="Patient/dicom"/> 
</subject> 
<context> 
  <display value="Encounter 1"/> 
</context> 
<occurrenceDateTime value="2013-05-08T09:33:27+07:00"/> 
<authoredOn value="2013-05-08T09:33:27+07:00"/> 
<requester> 
  <reference value="Practitioner/example"/> 
  <display value="Dr. Adam Careful"/> 
</requester> 
<performerType> 
  <coding> 
    <display value="Qualified nurse"/> 
  </coding> 
  <text value="Nurse"/> 
</performerType> 
<performer> 
  <display value="Nurse Rossignol"/> 
</performer> 
<reasonCode> 
  <text value="gastroparesis"/> 
</reasonCode> 
<reasonReference> 
  <display value="Gastroparesis"/> 
</reasonReference> 
<supportingInfo> 
  <display value="Previous results"/> 
</supportingInfo> 
<note> 
  <text value="this is the right device brand and model"/> 
</note> 
<relevantHistory> 
  <display value="Request for unspecified device"/> 
</relevantHistory> 
</DeviceRequest> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.