General DeviceMetric example (id = "example")

<?xml version="1.0" encoding="UTF-8"?>

<DeviceMetric xmlns="http://hl7.org/fhir">
  <id value="example"/> 
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : example</p> <p> <b> identifier</b> : 345675</p> <p> <b> type</b> : MDC_PULS_OXIM_SAT_O2 <span> (Details : {urn:iso:std:iso:11073:10101 code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})</span> </p> <p> <b> unit</b> : MDC_DIM_PERCENT <span> (Details : {urn:iso:std:iso:11073:10101 code '262688' = '262688', given as 'MDC_DIM_PERCENT'})</span> </p> <p> <b> source</b> : <a> Device/dev1</a> </p> <p> <b> parent</b> : <a> DeviceDefinition/dc102</a> </p> <p> <b> operationalStatus</b> : on</p> <p> <b> color</b> : blue</p> <p> <b> category</b> : measurement</p> <p> <b> measurementPeriod</b> : Do Once per 1 seconds</p> <h3> Calibrations</h3> <table> <tr> <td> -</td> <td> <b> Type</b> </td> <td> <b> State</b> </td> <td> <b> Time</b> </td> </tr> <tr> <td> *</td> <td> two-point</td> <td> calibrated</td> <td> 28/12/2016 9:03:04 AM</td> </tr> </table> </div> </text> <identifier> 
    <system value="http://goodcare.org/devicemetric/id"/> 
    <value value="345675"/> 
  </identifier> 
  <type> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="150456"/> 
      <display value="MDC_PULS_OXIM_SAT_O2"/> 
    </coding> 
  </type> 
  <unit> 
    <coding> 
      <system value="urn:iso:std:iso:11073:10101"/> 
      <code value="262688"/> 
      <display value="MDC_DIM_PERCENT"/> 
    </coding> 
  </unit> 
  <source> 
    <reference value="Device/dev1"/> 
  </source> 
  <parent> 
    <reference value="DeviceDefinition/dc102"/> 
  </parent> 
  <operationalStatus value="on"/> 
  <color value="blue"/> 
  <category value="measurement"/> 
  <measurementPeriod> 
    <repeat> 
      <frequency value="1"/> 
      <period value="1"/> 
      <periodUnit value="s"/> 
    </repeat> 
  </measurementPeriod> 
  <calibration> 
    <type value="two-point"/> 
    <state value="calibrated"/> 
    <time value="2016-12-28T09:03:04-05:00"/> 
  </calibration> 
</DeviceMetric> 

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.