This page is part of the FHIR Specification (v3.5.0: R4 Ballot #2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Health Care Devices Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Not linked to any defined compartments |
Raw Turtle (+ also see Turtle/RDF Format Specification)
General DeviceMetric example
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/DeviceMetric/example> a fhir:DeviceMetric; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "example"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>identifier</b>: 345675</p><p><b>type</b>: MDC_PULS_OXIM_SAT_O2 <span>(Details : {urn:iso:std:iso:11073:10101 code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})</span></p><p><b>unit</b>: MDC_DIM_PERCENT <span>(Details : {urn:iso:std:iso:11073:10101 code '262688' = '262688', given as 'MDC_DIM_PERCENT'})</span></p><p><b>source</b>: <a>Device/dev1</a></p><p><b>parent</b>: <a>DeviceDefinition/dc102</a></p><p><b>operationalStatus</b>: on</p><p><b>color</b>: blue</p><p><b>category</b>: measurement</p><p><b>measurementPeriod</b>: Do Once per 1 seconds</p><h3>Calibrations</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>State</b></td><td><b>Time</b></td></tr><tr><td>*</td><td>two-point</td><td>calibrated</td><td>28/12/2016 9:03:04 AM</td></tr></table></div>" ]; fhir:DeviceMetric.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "http://goodcare.org/devicemetric/id" ]; fhir:Identifier.value [ fhir:value "345675" ] ]; fhir:DeviceMetric.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "150456" ]; fhir:Coding.display [ fhir:value "MDC_PULS_OXIM_SAT_O2" ] ] ]; fhir:DeviceMetric.unit [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "urn:iso:std:iso:11073:10101" ]; fhir:Coding.code [ fhir:value "262688" ]; fhir:Coding.display [ fhir:value "MDC_DIM_PERCENT" ] ] ]; fhir:DeviceMetric.source [ fhir:link <http://hl7.org/fhir/Device/dev1>; fhir:Reference.reference [ fhir:value "Device/dev1" ] ]; fhir:DeviceMetric.parent [ fhir:link <http://hl7.org/fhir/DeviceDefinition/dc102>; fhir:Reference.reference [ fhir:value "DeviceDefinition/dc102" ] ]; fhir:DeviceMetric.operationalStatus [ fhir:value "on"]; fhir:DeviceMetric.color [ fhir:value "blue"]; fhir:DeviceMetric.category [ fhir:value "measurement"]; fhir:DeviceMetric.measurementPeriod [ fhir:Timing.repeat [ fhir:Timing.repeat.frequency [ fhir:value "1"^^xsd:positiveInteger ]; fhir:Timing.repeat.period [ fhir:value "1"^^xsd:decimal ]; fhir:Timing.repeat.periodUnit [ fhir:value "s" ] ] ]; fhir:DeviceMetric.calibration [ fhir:index 0; fhir:DeviceMetric.calibration.type [ fhir:value "two-point" ]; fhir:DeviceMetric.calibration.state [ fhir:value "calibrated" ]; fhir:DeviceMetric.calibration.time [ fhir:value "2016-12-28T09:03:04-05:00"^^xsd:dateTime ] ] . <http://hl7.org/fhir/Device/dev1> a fhir:Device . <http://hl7.org/fhir/DeviceDefinition/dc102> a fhir:DeviceDefinition . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/DeviceMetric/example.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/DeviceMetric/example.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.