R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2

Observation-example-unsat.xml

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw XML (canonical form)

Jump past Narrative

Specimen Reject Example (id = "unsat")

<Observation xmlns="http://hl7.org/fhir">
  <id value="unsat"/> 
<!--     urn:oid:2.16.840.1.113883.4.642.1.7     -->
<!--     2.16.840.1.113883.4.642.1.118     -->
  <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : unsat</p> <p> <b> identifier</b> : 6323 (OFFICIAL)</p> <p> <b> status</b> : cancelled</p> <p> <b> code</b> : Glucose [Moles/volume] in Blood <span> (Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose
           [Moles/volume] in Blood'})</span> </p> <p> <b> subject</b> : <a> P. van de Heuvel</a> </p> <p> <b> effective</b> : 02/04/2013 9:30:10 AM --&gt; 05/04/2013 9:30:10 AM</p> <p> <b> issued</b> : 03/04/2013 3:30:10 PM</p> <p> <b> performer</b> : <a> A. Langeveld</a> </p> <p> <b> dataAbsentReason</b> : Specimen unsatisfactory for evaluation <span> (Details : {SNOMED CT code '125154007' = 'Specimen unsatisfactory for evaluation', given
           as 'Specimen unsatisfactory for evaluation'})</span> </p> <p> <b> comment</b> : Tube broken in transit and sample leaked</p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 3.1 mmol/l<span>  (Details: UCUM code mmol/L = 'mmol/L')</span> </td> <td> 6.2 mmol/l<span>  (Details: UCUM code mmol/L = 'mmol/L')</span> </td> </tr> </table> </div> </text> <identifier> 
    <use value="official"/> 
    <system value="http://www.bmc.nl/zorgportal/identifiers/observations"/> 
    <value value="6323"/> 
  </identifier> 
  <status value="cancelled"/> 
  <code> 
    <coding> 
      <system value="http://loinc.org"/> 
      <code value="15074-8"/> 
      <display value="Glucose [Moles/volume] in Blood"/> 
    </coding> 
  </code> 
  <subject> 
    <reference value="Patient/f001"/> 
    <display value="P. van de Heuvel"/> 
  </subject> 
  <effectivePeriod> 
    <start value="2013-04-02T09:30:10+01:00"/> 
    <end value="2013-04-05T09:30:10+01:00"/> 
  </effectivePeriod> 
  <issued value="2013-04-03T15:30:10+01:00"/> 
  <performer> 
    <reference value="Practitioner/f005"/> 
    <display value="A. Langeveld"/> 
  </performer> 
  <dataAbsentReason> 
    <coding> 
      <system value="http://snomed.info/sct"/> 
      <code value="125154007"/> 
      <display value="Specimen unsatisfactory for evaluation"/> 
    </coding> 
  </dataAbsentReason> 
  <comment value="Tube broken in transit and sample leaked"/> 
  <referenceRange> 
    <low> 
      <value value="3.1"/> 
      <unit value="mmol/l"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="mmol/L"/> 
    </low> 
    <high> 
      <value value="6.2"/> 
      <unit value="mmol/l"/> 
      <system value="http://unitsofmeasure.org"/> 
      <code value="mmol/L"/> 
    </high> 
  </referenceRange> 
</Observation> 