This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Specimen Reject Example
@prefix fhir: <http://hl7.org/fhir/> . @prefix loinc: <http://loinc.org/rdf#> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Observation/unsat> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "unsat"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: unsat</p><p><b>identifier</b>: 6323 (OFFICIAL)</p><p><b>status</b>: cancelled</p><p><b>code</b>: Glucose [Moles/volume] in Blood <span>(Details : {LOINC code '15074-8' = 'Glucose [Moles/volume] in Blood', given as 'Glucose [Moles/volume] in Blood'})</span></p><p><b>subject</b>: <a>P. van de Heuvel</a></p><p><b>effective</b>: 02/04/2013 9:30:10 AM --> 05/04/2013 9:30:10 AM</p><p><b>issued</b>: 03/04/2013 3:30:10 PM</p><p><b>performer</b>: <a>A. Langeveld</a></p><p><b>dataAbsentReason</b>: Specimen unsatisfactory for evaluation <span>(Details : {SNOMED CT code '125154007' = 'Specimen unsatisfactory for evaluation', given as 'Specimen unsatisfactory for evaluation'})</span></p><p><b>comment</b>: Tube broken in transit and sample leaked</p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>3.1 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td><td>6.2 mmol/l<span> (Details: UCUM code mmol/L = 'mmol/L')</span></td></tr></table></div>" ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.use [ fhir:value "official" ]; fhir:Identifier.system [ fhir:value "http://www.bmc.nl/zorgportal/identifiers/observations" ]; fhir:Identifier.value [ fhir:value "6323" ] ]; fhir:Observation.status [ fhir:value "cancelled"]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; a loinc:15074-8; fhir:Coding.system [ fhir:value "http://loinc.org" ]; fhir:Coding.code [ fhir:value "15074-8" ]; fhir:Coding.display [ fhir:value "Glucose [Moles/volume] in Blood" ] ] ]; fhir:Observation.subject [ fhir:link <http://hl7.org/fhir/Patient/f001>; fhir:Reference.reference [ fhir:value "Patient/f001" ]; fhir:Reference.display [ fhir:value "P. van de Heuvel" ] ]; fhir:Observation.effectivePeriod [ fhir:Period.start [ fhir:value "2013-04-02T09:30:10+01:00"^^xsd:dateTime ]; fhir:Period.end [ fhir:value "2013-04-05T09:30:10+01:00"^^xsd:dateTime ] ]; fhir:Observation.issued [ fhir:value "2013-04-03T15:30:10+01:00"^^xsd:dateTime]; fhir:Observation.performer [ fhir:index 0; fhir:link <http://hl7.org/fhir/Practitioner/f005>; fhir:Reference.reference [ fhir:value "Practitioner/f005" ]; fhir:Reference.display [ fhir:value "A. Langeveld" ] ]; fhir:Observation.dataAbsentReason [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:125154007; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "125154007" ]; fhir:Coding.display [ fhir:value "Specimen unsatisfactory for evaluation" ] ] ]; fhir:Observation.comment [ fhir:value "Tube broken in transit and sample leaked"]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "3.1"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "6.2"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ] ] . <http://hl7.org/fhir/Patient/f001> a fhir:Patient . <http://hl7.org/fhir/Practitioner/f005> a fhir:Practitioner . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Observation/unsat.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/Observation/unsat.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.