R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4

Observation-example-secondsmoke.ttl

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw Turtle,

An example of a finding of second hand smoke exposure

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Observation/secondsmoke> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "secondsmoke"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: secondsmoke</p><p><b>status</b>: final</p><p><b>category</b>: Social History <span>(Details : {http://hl7.org/fhir/observation-category code 'social-history' = 'Social History', given as 'Social History'})</span></p><p><b>code</b>: Second hand smoke exposure <span>(Details : {LOINC code '39243-1' = 'Second hand smoke exposure CPHS', given as 'Second hand smoke exposure CPHS'}; {SNOMED CT code '102409004' = 'Second hand cigarette smoke', given as 'Second hand cigarette smoke (substance)'})</span></p><p><b>subject</b>: <a>Patient/infant</a></p><p><b>effective</b>: 18/05/2016 10:33:22 PM</p><p><b>value</b>: YES <span>(Details : {SNOMED CT code '373066001' = 'Yes', given as 'Yes (qualifier value)'})</span></p></div>"
  ];
  fhir:Observation.status [ fhir:value "final"];
  fhir:Observation.category [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/observation-category" ];
       fhir:Coding.code [ fhir:value "social-history" ];
       fhir:Coding.display [ fhir:value "Social History" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Social History" ]
  ];
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a loinc:39243-1;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "39243-1" ];
       fhir:Coding.display [ fhir:value "Second hand smoke exposure CPHS" ]
     ], [
       fhir:index 1;
       a sct:102409004;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "102409004" ];
       fhir:Coding.display [ fhir:value "Second hand cigarette smoke (substance)" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Second hand smoke exposure" ]
  ];
  fhir:Observation.subject [
     fhir:link <http://hl7.org/fhir/Patient/infant>;
     fhir:Reference.reference [ fhir:value "Patient/infant" ]
  ];
  fhir:Observation.effectiveDateTime [ fhir:value "2016-05-18T22:33:22Z"^^xsd:dateTime];
  fhir:Observation.valueCodeableConcept [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:373066001;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "373066001" ];
       fhir:Coding.display [ fhir:value "Yes (qualifier value)" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "YES" ]
  ] .

<http://hl7.org/fhir/Patient/infant> a fhir:Patient .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/Observation/secondsmoke.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/Observation/secondsmoke.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.