This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Oxygen Saturation by Pulse Oximetry Example (DeviceMetricObservation profile) (id = "satO2")
<Observation xmlns="http://hl7.org/fhir"> <id value="satO2"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/vitalsigns"/> </meta> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : satO2</p> <p> <b> meta</b> : </p> <p> <b> identifier</b> : o1223435-10</p> <p> <b> partOf</b> : <a> Procedure/ob</a> </p> <p> <b> status</b> : final</p> <p> <b> category</b> : Vital Signs <span> (Details : {http://hl7.org/fhir/observation-category code 'vital-signs' = 'Vital Signs', given as 'Vital Signs'})</span> </p> <p> <b> code</b> : Oxygen saturation in Arterial blood by Pulse oximetry <span> (Details : {LOINC code '59408-5' = 'Oxygen saturation in Arterial blood by Pulse oximetry', given as 'Oxygen saturation in Arterial blood by Pulse oximetry'}; {urn:iso:std:iso:11073:10101 code '150456' = '150456', given as 'MDC_PULS_OXIM_SAT_O2'})</span> </p> <p> <b> subject</b> : <a> Patient/example</a> </p> <p> <b> effective</b> : 05/12/2014 9:30:10 AM</p> <p> <b> value</b> : 95 %<span> (Details: UCUM code % = '%')</span> </p> <p> <b> interpretation</b> : Normal (applies to non-numeric results) <span> (Details : {http://hl7.org/fhir/v2/0078 code 'N' = 'Normal', given as 'Normal'})</span> </p> <p> <b> device</b> : <a> DeviceMetric/example</a> </p> <h3> ReferenceRanges</h3> <table> <tr> <td> -</td> <td> <b> Low</b> </td> <td> <b> High</b> </td> </tr> <tr> <td> *</td> <td> 90 %<span> (Details: UCUM code % = '%')</span> </td> <td> 99 %<span> (Details: UCUM code % = '%')</span> </td> </tr> </table> </div> </text> <identifier> <system value="http://goodcare.org/observation/id"/> <value value="o1223435-10"/> </identifier> <partOf> <reference value="Procedure/ob"/> </partOf> <status value="final"/> <category> <coding> <system value="http://hl7.org/fhir/observation-category"/> <code value="vital-signs"/> <display value="Vital Signs"/> </coding> <text value="Vital Signs"/> </category> <code> <coding> <system value="http://loinc.org"/> <!-- LOINC --> <code value="59408-5"/> <display value="Oxygen saturation in Arterial blood by Pulse oximetry"/> </coding> <!-- Example of a translation to a more specific code to the vitals profile LOINC code --> <coding> <system value="urn:iso:std:iso:11073:10101"/> <!-- mdc --> <code value="150456"/> <display value="MDC_PULS_OXIM_SAT_O2"/> </coding> </code> <subject> <reference value="Patient/example"/> </subject> <effectiveDateTime value="2014-12-05T09:30:10+01:00"/> <valueQuantity> <value value="95"/> <unit value="%"/> <system value="http://unitsofmeasure.org"/> <code value="%"/> </valueQuantity> <interpretation> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="N"/> <display value="Normal"/> </coding> <text value="Normal (applies to non-numeric results)"/> </interpretation> <device> <reference value="DeviceMetric/example"/> </device> <referenceRange> <low> <value value="90"/> <unit value="%"/> <system value="http://unitsofmeasure.org"/> <code value="%"/> </low> <high> <value value="99"/> <unit value="%"/> <system value="http://unitsofmeasure.org"/> <code value="%"/> </high> </referenceRange> </Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.