This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3 R2
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Encounter, Patient, Practitioner, RelatedPerson |
Real-world patient - staphylococcus (id = "f206")
<Observation xmlns="http://hl7.org/fhir"> <id value="f206"/> <text> <status value="generated"/> <div xmlns="http://www.w3.org/1999/xhtml"><p> <b> Generated Narrative with Details</b> </p> <p> <b> id</b> : f206</p> <p> <b> status</b> : final</p> <p> <b> code</b> : Blood culture <span> (Details : {http://acmelabs.org code '104177' = '104177', given as 'Blood culture'}; {LOINC code '600-7' = 'Bacteria identified in Blood by Culture', given as 'Bacteria identified in Blood by Culture'})</span> </p> <p> <b> subject</b> : <a> Roel</a> </p> <p> <b> issued</b> : 11/03/2013 10:28:00 AM</p> <p> <b> performer</b> : <a> Luigi Maas</a> </p> <p> <b> value</b> : Staphylococcus aureus <span> (Details : {SNOMED CT code '3092008' = 'Staphylococcus aureus', given as 'Staphylococcus aureus'})</span> </p> <p> <b> interpretation</b> : Positive <span> (Details : {http://hl7.org/fhir/v2/0078 code 'POS' = 'Positive)</span> </p> <p> <b> method</b> : Blood culture for bacteria, including anaerobic screen <span> (Details : {SNOMED CT code '104177005' = 'Blood culture for bacteria, including anaerobic screen', given as 'Blood culture for bacteria, including anaerobic screen'})</span> </p> </div> </text> <status value="final"/> <code> <!-- Kind of observation = Blood culture --><coding> <system value="http://acmelabs.org"/> <code value="104177"/> <display value="Blood culture"/> </coding> <coding> <system value="http://loinc.org"/> <code value="600-7"/> <display value="Bacteria identified in Blood by Culture"/> </coding> </code> <!-- No identifier could be provided to this observation --><subject> <reference value="Patient/f201"/> <display value="Roel"/> </subject> <issued value="2013-03-11T10:28:00+01:00"/> <performer> <reference value="Practitioner/f202"/> <display value="Luigi Maas"/> </performer> <valueCodeableConcept> <coding> <system value="http://snomed.info/sct"/> <code value="3092008"/> <display value="Staphylococcus aureus"/> </coding> </valueCodeableConcept> <interpretation> <coding> <system value="http://hl7.org/fhir/v2/0078"/> <code value="POS"/> </coding> </interpretation> <!-- BodySite not relevant --><method> <coding> <system value="http://snomed.info/sct"/> <code value="104177005"/> <display value="Blood culture for bacteria, including anaerobic screen"/> </coding> </method> <!-- ReferenceRange and component are not applicable --></Observation>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.