R4 Ballot #1 (Mixed Normative/Trial use)

This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Observation-example-f202-temperature.ttl

Orders and Observations Work GroupMaturity Level: N/ABallot Status: InformativeCompartments: Device, Encounter, Patient, Practitioner, RelatedPerson

Raw Turtle,

Real-world patient - temperature

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/rdf#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Observation/f202> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "f202"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: f202</p><p><b>status</b>: entered-in-error</p><p><b>category</b>: Vital Signs <span>(Details : {http://hl7.org/fhir/observation-category code 'vital-signs' = 'Vital Signs', given as 'Vital Signs'})</span></p><p><b>code</b>: Temperature <span>(Details : {http://acme.lab code 'BT' = 'BT', given as 'Body temperature'}; {LOINC code '8310-5' = 'Body temperature', given as 'Body temperature'}; {LOINC code '8331-1' = 'Oral temperature', given as 'Oral temperature'}; {SNOMED CT code '56342008' = 'Temperature taking', given as 'Temperature taking'})</span></p><p><b>subject</b>: <a>Roel</a></p><p><b>issued</b>: 04/04/2013 1:27:00 PM</p><p><b>performer</b>: <a>Practitioner/f201</a></p><p><b>value</b>: 39 degrees C<span> (Details: UCUM code Cel = 'Cel')</span></p><p><b>interpretation</b>: High <span>(Details : {http://hl7.org/fhir/v2/0078 code 'H' = 'High)</span></p><p><b>bodySite</b>: Oral cavity <span>(Details : {SNOMED CT code '74262004' = 'Oral cavity', given as 'Oral cavity'})</span></p><p><b>method</b>: Oral temperature taking <span>(Details : {SNOMED CT code '89003005' = 'Oral temperature taking', given as 'Oral temperature taking'})</span></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>High</b></td></tr><tr><td>*</td><td>38.2 degrees C</td></tr></table></div>"
  ];
  fhir:Observation.status [ fhir:value "entered-in-error"];
  fhir:Observation.category [
     fhir:index 0;
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/observation-category" ];
       fhir:Coding.code [ fhir:value "vital-signs" ];
       fhir:Coding.display [ fhir:value "Vital Signs" ]
     ]
  ];
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://acme.lab" ];
       fhir:Coding.code [ fhir:value "BT" ];
       fhir:Coding.display [ fhir:value "Body temperature" ]
     ], [
       fhir:index 1;
       a loinc:8310-5;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "8310-5" ];
       fhir:Coding.display [ fhir:value "Body temperature" ]
     ], [
       fhir:index 2;
       a loinc:8331-1;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "8331-1" ];
       fhir:Coding.display [ fhir:value "Oral temperature" ]
     ], [
       fhir:index 3;
       a sct:56342008;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "56342008" ];
       fhir:Coding.display [ fhir:value "Temperature taking" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Temperature" ]
  ];
  fhir:Observation.subject [
     fhir:link <http://hl7.org/fhir/Patient/f201>;
     fhir:Reference.reference [ fhir:value "Patient/f201" ];
     fhir:Reference.display [ fhir:value "Roel" ]
  ];
  fhir:Observation.issued [ fhir:value "2013-04-04T13:27:00+01:00"^^xsd:dateTime];
  fhir:Observation.performer [
     fhir:index 0;
     fhir:link <http://hl7.org/fhir/Practitioner/f201>;
     fhir:Reference.reference [ fhir:value "Practitioner/f201" ]
  ];
  fhir:Observation.valueQuantity [
     fhir:Quantity.value [ fhir:value "39"^^xsd:decimal ];
     fhir:Quantity.unit [ fhir:value "degrees C" ];
     fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
     fhir:Quantity.code [ fhir:value "Cel" ]
  ];
  fhir:Observation.interpretation [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ];
       fhir:Coding.code [ fhir:value "H" ]
     ]
  ];
  fhir:Observation.bodySite [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:74262004;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "74262004" ];
       fhir:Coding.display [ fhir:value "Oral cavity" ]
     ]
  ];
  fhir:Observation.method [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       a sct:89003005;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "89003005" ];
       fhir:Coding.display [ fhir:value "Oral temperature taking" ]
     ]
  ];
  fhir:Observation.referenceRange [
     fhir:index 0;
     fhir:Observation.referenceRange.high [
       fhir:Quantity.value [ fhir:value "38.2"^^xsd:decimal ];
       fhir:Quantity.unit [ fhir:value "degrees C" ]
     ]
  ] .

<http://hl7.org/fhir/Patient/f201> a fhir:Patient .

<http://hl7.org/fhir/Practitioner/f201> a fhir:Practitioner .

# - ontology header ------------------------------------------------------------

<http://hl7.org/fhir/Observation/f202.ttl> a owl:Ontology;
  owl:imports fhir:fhir.ttl;
  owl:versionIRI <http://build.fhir.org/Observation/f202.ttl> .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.