This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4B R4 R3
Security Work Group | Maturity Level: N/A | Ballot Status: Informative |
SOPClass
{ "resourceType": "StructureDefinition", "id": "auditevent-SOPClass", "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg", "valueCode": "sec" }, { "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm", "valueInteger": 1 } ], "url": "http://hl7.org/fhir/StructureDefinition/auditevent-SOPClass", "name": "SOPClass", "status": "draft", "date": "2018-04-03T12:05:46+10:00", "publisher": "Health Level Seven, Inc. - Security WG", "contact": [ { "telecom": [ { "system": "url", "value": "http://www.hl7.org/Special/committees/security/index.cfm" } ] } ], "description": "Required if ParticipantObjectIDTypeCode is (110180, DCM, \"Study Instance UID\") and any of the optional fields (AccessionNumber, ContainsMPPS, NumberOfInstances, ContainsSOPInstances,Encrypted,Anonymized) are present in this Participant Object. May be present if ParticipantObjectIDTypeCode is (110180, DCM, \"Study Instance UID\") even though none of the optional fields are present.", "fhirVersion": "3.3.0", "mapping": [ { "identity": "dicom", "uri": "http://nema.org/dicom", "name": "DICOM Tag Mapping" }, { "identity": "rim", "uri": "http://hl7.org/v3", "name": "RIM Mapping" } ], "kind": "complex-type", "abstract": false, "context": [ { "type": "element", "expression": "AuditEvent.entity" } ], "type": "Extension", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension", "derivation": "constraint", "snapshot": { "element": [ { "id": "Extension", "path": "Extension", "short": "UIDs of SOP classes referred to", "definition": "Required if ParticipantObjectIDTypeCode is (110180, DCM, \"Study Instance UID\") and any of the optional fields (AccessionNumber, ContainsMPPS, NumberOfInstances, ContainsSOPInstances,Encrypted,Anonymized) are present in this Participant Object. May be present if ParticipantObjectIDTypeCode is (110180, DCM, \"Study Instance UID\") even though none of the optional fields are present.", "min": 0, "max": "*", "base": { "path": "Extension", "min": 0, "max": "*" }, "condition": [ "ele-1" ], "constraint": [ { "key": "ele-1", "severity": "error", "human": "All FHIR elements must have a @value or children", "expression": "hasValue() | (children().count() > id.count())", "xpath": "@value|f:*|h:div", "source": "Element" }, { "key": "ext-1", "severity": "error", "human": "Must have either extensions or value[x], not both", "expression": "extension.exists() != value.exists()", "xpath": "exists(f:extension)!=exists(f:*[starts-with(local-name(.), 'value')])", "source": "Extension" } ], "isModifier": false, "mapping": [ { "identity": "dicom", "map": "SOPClass" } ] }, { "id": "Extension.id", "path": "Extension.id", "representation": [ "xmlAttr" ], "short": "xml:id (or equivalent in JSON)", "definition": "Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.", "min": 0, "max": "1", "base": { "path": "Element.id", "min": 0, "max": "1" }, "type": [ { "code": "string" } ], "isModifier": false, "isSummary": false, "mapping": [ { "identity": "rim", "map": "n/a" } ] }, { "id": "Extension.extension", "path": "Extension.extension", "slicing": { "discriminator": [ { "type": "value", "path": "url" } ], "description": "Extensions are always sliced by (at least) url", "rules": "open" }, "short": "Extension", "definition": "An Extension", "min": 0, "max": "0", "base": { "path": "Element.extension", "min": 0, "max": "*" }, "type": [ { "code": "Extension" } ], "isModifier": false, "isSummary": false }, { "id": "Extension.url", "path": "Extension.url", "representation": [ "xmlAttr" ], "short": "identifies the meaning of the extension", "definition": "Source of the definition for the extension code - a logical name or a URL.", "comment": "The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension.", "min": 1, "max": "1", "base": { "path": "Extension.url", "min": 1, "max": "1" }, "type": [ { "code": "uri" } ], "fixedUri": "http://hl7.org/fhir/StructureDefinition/auditevent-SOPClass", "isModifier": false, "isSummary": false, "mapping": [ { "identity": "rim", "map": "N/A" } ] }, { "id": "Extension.valueReference", "path": "Extension.valueReference", "short": "Value of extension", "definition": "Value of extension - may be a resource or one of a constrained set of the data types (see Extensibility in the spec for list).", "min": 0, "max": "1", "base": { "path": "Extension.value[x]", "min": 0, "max": "1" }, "type": [ { "code": "Reference", "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/ImagingStudy" ] } ], "isModifier": false, "isSummary": false, "mapping": [ { "identity": "rim", "map": "N/A" } ] } ] }, "differential": { "element": [ { "id": "Extension", "path": "Extension", "short": "UIDs of SOP classes referred to", "definition": "Required if ParticipantObjectIDTypeCode is (110180, DCM, \"Study Instance UID\") and any of the optional fields (AccessionNumber, ContainsMPPS, NumberOfInstances, ContainsSOPInstances,Encrypted,Anonymized) are present in this Participant Object. May be present if ParticipantObjectIDTypeCode is (110180, DCM, \"Study Instance UID\") even though none of the optional fields are present.", "min": 0, "max": "*", "mapping": [ { "identity": "dicom", "map": "SOPClass" } ] }, { "id": "Extension.extension", "path": "Extension.extension", "max": "0" }, { "id": "Extension.url", "path": "Extension.url", "type": [ { "code": "uri" } ], "fixedUri": "http://hl7.org/fhir/StructureDefinition/auditevent-SOPClass" }, { "id": "Extension.valueReference", "path": "Extension.valueReference", "type": [ { "code": "Reference", "targetProfile": [ "http://hl7.org/fhir/StructureDefinition/ImagingStudy" ] } ] } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.