This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5R4BR4R3R2
Mappings for the devicemetricobservation Profile (see Mappings to Other Standards for further information & status)
10.1.11.4 Mappings for Workflow Pattern (http://hl7.org/fhir/workflow)
Device Metric Observation Profile
Observation
Event
id
meta
implicitRules
language
text
contained
extension
modifierExtension
identifier
Event.identifier
basedOn
Event.basedOn
partOf
Event.partOf
status
Event.status
category
code
Event.code
subject
Event.subject
focus
effectiveDateTime
Event.occurrence[x]
performer
Event.performer.actor
value[x]
interpretation
comment
bodySite
method
device
referenceRange
id
extension
modifierExtension
low
high
type
appliesTo
age
text
hasMember
derivedFrom
component
id
extension
modifierExtension
code
value[x]
dataAbsentReason
interpretation
referenceRange
10.1.11.5 Mappings for SNOMED CT Concept Domain Binding (http://snomed.info/conceptdomain)
Concept domain bindings link a resource or an element to a set of SNOMED CT concepts that represent the intended semantics of the instances (whether or not SNOMED CT is used to encode that data element).
This set of concepts is represented using a SNOMED CT expression constraint. Note that the 'Concept domain binding' may be a superset of the 'value set binding'. These bindings help to support:
Quality checking FHIR resources by ensuring that (a) the intended semantics of the instances matches the valid range of the corresponding SNOMED CT attribute, and (b) the intended value set is appropriate for the intended semantics of the instances
Semantic checking of data instances by helping to detect potential inconsistencies caused by overlap between the semantics incorporated in two concept domains
Device Metric Observation Profile
Observation
< 363787002 |Observable entity|
id
meta
implicitRules
language
text
contained
extension
modifierExtension
identifier
basedOn
partOf
status
< 445584004 |Report by finality status|
category
code
< 363787002 |Observable entity| OR < 386053000 |Evaluation procedure|
subject
focus
effectiveDateTime
performer
value[x]
< 441742003 |Evaluation finding|
interpretation
< 260245000 |Findings values|
comment
bodySite
< 123037004 |Body structure|
method
device
< 49062001 |Device|
referenceRange
id
extension
modifierExtension
low
high
type
< 260245000 |Findings values| OR
< 365860008 |General clinical state finding|
OR
< 250171008 |Clinical history or observation findings| OR
< 415229000 |Racial group| OR
< 365400002 |Finding of puberty stage| OR
< 443938003 |Procedure carried out on subject|
appliesTo
< 260245000 |Findings values| OR
< 365860008 |General clinical state finding|
OR
< 250171008 |Clinical history or observation findings| OR
< 415229000 |Racial group| OR
< 365400002 |Finding of puberty stage| OR
< 443938003 |Procedure carried out on subject|
age
text
hasMember
derivedFrom
component
id
extension
modifierExtension
code
< 363787002 |Observable entity| OR
< 386053000 |Evaluation procedure|
10.1.11.6 Mappings for HL7 v2 Mapping (http://hl7.org/v2)
Device Metric Observation Profile
Observation
OBX
id
meta
implicitRules
language
text
contained
extension
modifierExtension
identifier
OBX.21 For OBX segments from systems without OBX-21 support a combination of ORC/OBR and OBX must be negotiated between trading partners to uniquely identify the OBX segment. Depending on how V2 has been implemented each of these may be an option: 1) OBR-3 + OBX-3 + OBX-4 or 2) OBR-3 + OBR-4 + OBX-3 + OBX-4 or 2) some other way to uniquely ID the OBR/ORC + OBX-3 + OBX-4.
basedOn
ORC
partOf
Varies by domain
status
OBX-11
category
code
OBX-3
subject
PID-3
focus
OBX-3
effectiveDateTime
OBX-14, and/or OBX-19 after v2.4 (depends on who observation made)
10.1.11.8 Mappings for FiveWs Pattern (http://hl7.org/fhir/fivews)
Device Metric Observation Profile
Observation
id
meta
implicitRules
language
text
contained
extension
modifierExtension
identifier
FiveWs.identifier
basedOn
partOf
status
FiveWs.status
category
FiveWs.class
code
FiveWs.what[x]
subject
FiveWs.subject[x]
focus
FiveWs.subject[x]
effectiveDateTime
FiveWs.done[x]
performer
FiveWs.actor
value[x]
interpretation
comment
bodySite
method
device
referenceRange
id
extension
modifierExtension
low
high
type
appliesTo
age
text
hasMember
derivedFrom
component
id
extension
modifierExtension
code
FiveWs.what[x]
value[x]
dataAbsentReason
interpretation
referenceRange
10.1.11.9 Mappings for SNOMED CT Attribute Binding (http://snomed.info/sct)
Attribute bindings link coded data elements in FHIR resources to a corresponding attribute in the SNOMED CT concept model. These bindings help to support:
clarifying the intended meaning of the data element
Quality checking the alignment between FHIR resource design and any coresponding SNOMED CT concept model
Composition and decomposition of data instances by indicating the SNOMED CT concept model attribute whose value may be used to decompose a precoordinated concept into this data element