This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Orders and Observations Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device |
General Device Example
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Device/example> a fhir:Device; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "example"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example</p><p><b>identifier</b>: 345675, Serial Number = AMID-342135-8464</p><p><b>status</b>: active</p><p><b>type</b>: ECG <span>(Details : {SNOMED CT code '86184003' = 'Electrocardiographic monitor and recorder', given as 'Electrocardiographic monitor and recorder'})</span></p><p><b>lotNumber</b>: 43453424</p><p><b>manufacturer</b>: Acme Devices, Inc</p><p><b>model</b>: AB 45-J</p><p><b>contact</b>: ph: ext 4352</p><p><b>note</b>: QA Checked</p></div>" ]; fhir:Device.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "http://goodcare.org/devices/id" ]; fhir:Identifier.value [ fhir:value "345675" ] ], [ fhir:index 1; fhir:Identifier.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ]; fhir:Coding.code [ fhir:value "SNO" ] ]; fhir:CodeableConcept.text [ fhir:value "Serial Number" ] ]; fhir:Identifier.value [ fhir:value "AMID-342135-8464" ] ]; fhir:Device.status [ fhir:value "active"]; fhir:Device.type [ fhir:CodeableConcept.coding [ fhir:index 0; a sct:86184003; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "86184003" ]; fhir:Coding.display [ fhir:value "Electrocardiographic monitor and recorder" ] ]; fhir:CodeableConcept.text [ fhir:value "ECG" ] ]; fhir:Device.lotNumber [ fhir:value "43453424"]; fhir:Device.manufacturer [ fhir:value "Acme Devices, Inc"]; fhir:Device.model [ fhir:value "AB 45-J"]; fhir:Device.contact [ fhir:index 0; fhir:ContactPoint.system [ fhir:value "phone" ]; fhir:ContactPoint.value [ fhir:value "ext 4352" ] ]; fhir:Device.note [ fhir:index 0; fhir:Annotation.authorReference [ fhir:link <http://hl7.org/fhir/Practitioner/xcda-author>; fhir:Reference.reference [ fhir:value "Practitioner/xcda-author" ] ]; fhir:Annotation.time [ fhir:value "2015-06-28T14:03:32+10:00"^^xsd:dateTime ]; fhir:Annotation.text [ fhir:value "QA Checked" ] ] . <http://hl7.org/fhir/Practitioner/xcda-author> a fhir:Practitioner . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/Device/example.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/Device/example.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.