This page is part of the FHIR Specification (v3.3.0: R4 Ballot 2). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Clinical Decision Support Work Group | Maturity Level: N/A | Ballot Status: Informative | Compartments: Device, Patient, Practitioner |
Diagnostic order is placed when a recent image of the same body site already exists
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/DetectedIssue/duplicate> a fhir:DetectedIssue; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "duplicate"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n <p>Similar test was performed within the past 14 days</p>\n <ul>\n <li>\n <a href=\"ServiceRequest/id\">Chest CT - ordered May 8, 2013 by Dr. Adam Careful</a>\n </li>\n <li>\n <a href=\"ImagingStudy/example\">Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20 AM</a>\n </li>\n </ul>\n </div>" ]; fhir:DetectedIssue.identifier [ fhir:index 0; fhir:Identifier.use [ fhir:value "official" ]; fhir:Identifier.system [ fhir:value "http://example.org" ]; fhir:Identifier.value [ fhir:value "12345" ] ]; fhir:DetectedIssue.status [ fhir:value "final"]; fhir:DetectedIssue.category [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v3/ActCode" ]; fhir:Coding.code [ fhir:value "DUPTHPY" ]; fhir:Coding.display [ fhir:value "Duplicate Therapy Alert" ] ] ]; fhir:DetectedIssue.patient [ fhir:link <http://hl7.org/fhir/Patient/dicom>; fhir:Reference.reference [ fhir:value "Patient/dicom" ] ]; fhir:DetectedIssue.date [ fhir:value "2013-05-08"^^xsd:date]; fhir:DetectedIssue.author [ fhir:link <http://hl7.org/fhir/Device/software>; fhir:Reference.reference [ fhir:value "Device/software" ] ]; fhir:DetectedIssue.implicated [ fhir:index 0; fhir:link <http://hl7.org/fhir/ServiceRequest/di>; fhir:Reference.reference [ fhir:value "ServiceRequest/di" ]; fhir:Reference.display [ fhir:value "Chest CT - ordered May 8, 2013 by Dr. Adam Careful" ] ], [ fhir:index 1; fhir:link <http://hl7.org/fhir/ImagingStudy/example>; fhir:Reference.reference [ fhir:value "ImagingStudy/example" ]; fhir:Reference.display [ fhir:value "Image 1 from Series 3: CT Images on Patient MINT (MINT1234) taken at 1-Jan 2011 01:20 AM" ] ]; fhir:DetectedIssue.detail [ fhir:value "Similar test was performed within the past 14 days"]; fhir:DetectedIssue.reference [ fhir:value "http://www.tmhp.com/RadiologyClinicalDecisionSupport/2011/CHEST%20IMAGING%20GUIDELINES%202011.pdf"] . <http://hl7.org/fhir/Patient/dicom> a fhir:Patient . <http://hl7.org/fhir/Device/software> a fhir:Device . <http://hl7.org/fhir/ServiceRequest/di> a fhir:ServiceRequest . <http://hl7.org/fhir/ImagingStudy/example> a fhir:ImagingStudy . # - ontology header ------------------------------------------------------------ <http://hl7.org/fhir/DetectedIssue/duplicate.ttl> a owl:Ontology; owl:imports fhir:fhir.ttl; owl:versionIRI <http://build.fhir.org/DetectedIssue/duplicate.ttl> . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.