This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3
FHIR Value set/code system definition for HL7 v2 table 0369 ( Specimen Role)
<ValueSet xmlns="http://hl7.org/fhir"> <id value="v2-0369"/> <meta> <profile value="http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"/> </meta> <text> <status value="additional"/> <div xmlns="http://www.w3.org/1999/xhtml"> <p>Specimen Role</p> <table class="grid"> <tr> <td> <b>Code</b> </td> <td> <b>Description</b> </td> <td> <b>Nederlands (Dutch)</b> </td> <td> <b>Comment</b> </td> <td> <b>Version</b> </td> </tr> <tr> <td>B <a name="B"> </a> </td> <td>Blind Sample</td> <td>Blind monster</td> <td/> <td>added v2.4</td> </tr> <tr> <td>C <a name="C"> </a> </td> <td>Calibrator, used for initial setting of calibration</td> <td>Calibratie, gebruikt voor initiële calibratie</td> <td/> <td>added v2.4</td> </tr> <tr> <td>E <a name="E"> </a> </td> <td>Electronic QC, used with manufactured reference providing signals that simulate QC results</td> <td>Electronische QC, gebruikt met fabrieksreferentie die signalen afgeeft die QC-resultaten stimuleren</td> <td/> <td>added v2.5</td> </tr> <tr> <td>F <a name="F"> </a> </td> <td>Specimen used for testing proficiency of the organization performing the testing (Filler)</td> <td>Monster gebruikt voor testen van vakbekwaamheid van de organisatie die de testen uitvoert (Filler)</td> <td/> <td>added v2.5</td> </tr> <tr> <td>G <a name="G"> </a> </td> <td>Group (where a specimen consists of multiple individual elements that are not individually identified)</td> <td>Groep (waarbij een monster bestaat uit meerdere individuele elementen die niet individueel worden geïdenticeerd)</td> <td/> <td>added v2.5</td> </tr> <tr> <td>L <a name="L"> </a> </td> <td>Pool (aliquots of individual specimens combined to form a single specimen representing all of the components.)</td> <td>Pool (aliquots van individuele monsters gecombineerd tot een enkel monster dat alle componenten bevat.)</td> <td/> <td>added v2.5</td> </tr> <tr> <td>O <a name="O"> </a> </td> <td>Specimen used for testing Operator Proficiency</td> <td>Monster gebruikt voor het testen van de vakbekwaamheid van de operator</td> <td/> <td>added v2.5</td> </tr> <tr> <td>P <a name="P"> </a> </td> <td>Patient (default if blank component value)</td> <td>Patiënt (standaard indien component geen waarde heeft)</td> <td/> <td>added v2.4</td> </tr> <tr> <td>Q <a name="Q"> </a> </td> <td>Control specimen</td> <td>Control monster</td> <td/> <td>added v2.4</td> </tr> <tr> <td>R <a name="R"> </a> </td> <td>Replicate (of patient sample as a control)</td> <td>Replicatie (van patiëntmonster ter controle)</td> <td/> <td>added v2.4</td> </tr> <tr> <td>V <a name="V"> </a> </td> <td>Verifying Calibrator, used for periodic calibration checks</td> <td>Verificatie calibrator, gebruikt voor periodieke calibratietesten</td> <td/> <td>added v2.5</td> </tr> </table> </div> </text> <url value="http://hl7.org/fhir/ValueSet/v2-0369"/> <version value="2.8.2"/> <name value="v2 Specimen Role"/> <status value="active"/> <experimental value="true"/> <publisher value="HL7, Inc"/> <contact> <telecom> <system value="url"/> <value value="http://hl7.org"/> </telecom> </contact> <description value="FHIR Value set/code system definition for HL7 v2 table 0369 ( Specimen Role)"/> <immutable value="true"/> <compose> <include> <system value="http://hl7.org/fhir/v2/0369"/> </include> </compose> </ValueSet>
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.