This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
General Specimen Example
@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .
# - resource -------------------------------------------------------------------
<http://hl7.org/fhir/Specimen/101> a fhir:Specimen;
fhir:nodeRole fhir:treeRoot;
fhir:Resource.id [ fhir:value "101"];
fhir:DomainResource.text [
fhir:Narrative.status [ fhir:value "generated" ];
fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: 101</p><p><b>contained</b>: </p><p><b>identifier</b>: 23234352356</p><p><b>accessionIdentifier</b>: X352356</p><p><b>status</b>: available</p><p><b>type</b>: Venous blood specimen <span>(Details : {SNOMED CT code '122555007' = 'Venous blood specimen (specimen)', given as 'Venous blood specimen'})</span></p><p><b>subject</b>: <a>Peter Patient</a></p><p><b>receivedTime</b>: 04/03/2011 6:03:00 PM</p><p><b>request</b>: <a>DiagnosticRequest/example</a></p><h3>Collections</h3><table><tr><td>-</td><td><b>Collector</b></td><td><b>Collected[x]</b></td><td><b>Quantity</b></td><td><b>Method</b></td></tr><tr><td>*</td><td><a>Practitioner/example</a></td><td>30/05/2011 4:15:00 PM</td><td>6 mL</td><td>Line, Venous <span>(Details : {http://hl7.org/fhir/v2/0488 code 'LNV' = 'Line, Venous)</span></td></tr></table><h3>Containers</h3><table><tr><td>-</td><td><b>Identifier</b></td><td><b>Description</b></td><td><b>Type</b></td><td><b>Capacity</b></td><td><b>SpecimenQuantity</b></td><td><b>Additive[x]</b></td></tr><tr><td>*</td><td>48736-15394-75465</td><td>Green Gel tube</td><td>Vacutainer <span>(Details )</span></td><td>10 mL</td><td>6 mL</td><td>id: hep; Lithium/Li Heparin <span>(Details : {http://hl7.org/fhir/v3/EntityCode code 'HEPL' = 'Lithium/Li Heparin)</span></td></tr></table><p><b>note</b>: Specimen is grossly lipemic</p></div>"
];
fhir:DomainResource.contained [
a fhir:Substance;
fhir:index 0;
fhir:Resource.id [ fhir:value "hep" ];
fhir:Substance.code [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v3/EntityCode" ];
fhir:Coding.code [ fhir:value "HEPL" ]
]
]
];
fhir:Specimen.identifier [
fhir:index 0;
fhir:Identifier.system [ fhir:value "http://ehr.acme.org/identifiers/collections" ];
fhir:Identifier.value [ fhir:value "23234352356" ]
];
fhir:Specimen.accessionIdentifier [
fhir:Identifier.system [ fhir:value "http://lab.acme.org/specimens/2011" ];
fhir:Identifier.value [ fhir:value "X352356" ]
];
fhir:Specimen.status [ fhir:value "available"];
fhir:Specimen.type [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:concept sct:122555007;
fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
fhir:Coding.code [ fhir:value "122555007" ];
fhir:Coding.display [ fhir:value "Venous blood specimen" ]
]
];
fhir:Specimen.subject [
fhir:link <http://hl7.org/fhir/Patient/example>;
fhir:Reference.reference [ fhir:value "Patient/example" ];
fhir:Reference.display [ fhir:value "Peter Patient" ]
];
fhir:Specimen.receivedTime [ fhir:value "2011-03-04T07:03:00Z"^^xsd:dateTime];
fhir:Specimen.request [
fhir:index 0;
fhir:link <http://hl7.org/fhir/DiagnosticRequest/example>;
fhir:Reference.reference [ fhir:value "DiagnosticRequest/example" ]
];
fhir:Specimen.collection [
fhir:Specimen.collection.collector [
fhir:link <http://hl7.org/fhir/Practitioner/example>;
fhir:Reference.reference [ fhir:value "Practitioner/example" ]
];
fhir:Specimen.collection.collectedDateTime [ fhir:value "2011-05-30T06:15:00Z"^^xsd:dateTime ];
fhir:Specimen.collection.quantity [
fhir:Quantity.value [ fhir:value "6"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "mL" ]
];
fhir:Specimen.collection.method [
fhir:CodeableConcept.coding [
fhir:index 0;
fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0488" ];
fhir:Coding.code [ fhir:value "LNV" ]
]
]
];
fhir:Specimen.container [
fhir:index 0;
fhir:Specimen.container.identifier [
fhir:index 0;
fhir:Identifier.value [ fhir:value "48736-15394-75465" ]
];
fhir:Specimen.container.description [ fhir:value "Green Gel tube" ];
fhir:Specimen.container.type [
fhir:CodeableConcept.text [ fhir:value "Vacutainer" ]
];
fhir:Specimen.container.capacity [
fhir:Quantity.value [ fhir:value "10"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "mL" ]
];
fhir:Specimen.container.specimenQuantity [
fhir:Quantity.value [ fhir:value "6"^^xsd:decimal ];
fhir:Quantity.unit [ fhir:value "mL" ]
];
fhir:Specimen.container.additiveReference [
fhir:Reference.reference [ fhir:value "#hep" ]
]
];
fhir:Specimen.note [
fhir:index 0;
fhir:Annotation.text [ fhir:value "Specimen is grossly lipemic" ]
] .
<http://hl7.org/fhir/Patient/example> a fhir:Patient .
<http://hl7.org/fhir/DiagnosticRequest/example> a fhir:DiagnosticRequest .
<http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner .
# -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.