STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Observation-example-glasgow-qa.ttl

Raw Turtle, JSON-LD

Clinical assessment tool example - GCS using related QuestionnaireAnswer

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/owl#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Observation/gcs-qa> a fhir:Observation;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "gcs-qa"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: gcs-qa</p><p><b>status</b>: final</p><p><b>code</b>: Glasgow Coma Scale , (GCS) <span>(Details : {LOINC code '9269-2' = 'Glasgow coma score total', given as 'Glasgow coma score total'})</span></p><p><b>subject</b>: <a>Peter James Chalmers</a></p><p><b>effective</b>: 11/12/2014 3:44:16 PM</p><p><b>value</b>: 13 {score}<span> (Details: UCUM code {score} = '{score}')</span></p><blockquote><p><b>referenceRange</b></p><p><b>high</b>: 8 {score}<span> (Details: UCUM code {score} = '{score}')</span></p><p><b>meaning</b>: Severe TBI <span>(Details )</span></p></blockquote><blockquote><p><b>referenceRange</b></p><p><b>low</b>: 9 {score}<span> (Details: UCUM code {score} = '{score}')</span></p><p><b>high</b>: 12 {score}<span> (Details: UCUM code {score} = '{score}')</span></p><p><b>meaning</b>: Moderate TBI <span>(Details )</span></p></blockquote><blockquote><p><b>referenceRange</b></p><p><b>low</b>: 13 {score}<span> (Details: UCUM code {score} = '{score}')</span></p><p><b>meaning</b>: Mild TBI <span>(Details )</span></p></blockquote><h3>Relateds</h3><table><tr><td>-</td><td><b>Type</b></td><td><b>Target</b></td></tr><tr><td>*</td><td>derived-from</td><td><a>GCS form results</a></td></tr></table></div>"
  ];
  fhir:Observation.status [ fhir:value "final"];
  fhir:Observation.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:concept loinc:9269-2;
       fhir:Coding.system [ fhir:value "http://loinc.org" ];
       fhir:Coding.code [ fhir:value "9269-2" ];
       fhir:Coding.display [ fhir:value "Glasgow coma score total" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Glasgow Coma Scale , (GCS)" ]
  ];
  fhir:Observation.subject [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ];
     fhir:Reference.display [ fhir:value "Peter James Chalmers" ]
  ];
  fhir:Observation.effectiveDateTime [ fhir:value "2014-12-11T04:44:16Z"^^xsd:dateTime];
  fhir:Observation.valueQuantity [
     fhir:Quantity.value [ fhir:value "13"^^xsd:decimal ];
     fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
     fhir:Quantity.code [ fhir:value "{score}" ]
  ];
  fhir:Observation.referenceRange [
     fhir:index 0;
     fhir:Observation.referenceRange.high [
       fhir:Quantity.value [ fhir:value "8"^^xsd:decimal ];
       fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
       fhir:Quantity.code [ fhir:value "{score}" ]
     ];
     fhir:Observation.referenceRange.meaning [
       fhir:index 0;
       fhir:CodeableConcept.text [ fhir:value "Severe TBI" ]
     ]
  ], [
     fhir:index 1;
     fhir:Observation.referenceRange.low [
       fhir:Quantity.value [ fhir:value "9"^^xsd:decimal ];
       fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
       fhir:Quantity.code [ fhir:value "{score}" ]
     ];
     fhir:Observation.referenceRange.high [
       fhir:Quantity.value [ fhir:value "12"^^xsd:decimal ];
       fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
       fhir:Quantity.code [ fhir:value "{score}" ]
     ];
     fhir:Observation.referenceRange.meaning [
       fhir:index 0;
       fhir:CodeableConcept.text [ fhir:value "Moderate TBI" ]
     ]
  ], [
     fhir:index 2;
     fhir:Observation.referenceRange.low [
       fhir:Quantity.value [ fhir:value "13"^^xsd:decimal ];
       fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ];
       fhir:Quantity.code [ fhir:value "{score}" ]
     ];
     fhir:Observation.referenceRange.meaning [
       fhir:index 0;
       fhir:CodeableConcept.text [ fhir:value "Mild TBI" ]
     ]
  ];
  fhir:Observation.related [
     fhir:index 0;
     fhir:Observation.related.type [ fhir:value "derived-from" ];
     fhir:Observation.related.target [
       fhir:link <http://hl7.org/fhir/QuestionnaireResponse/gcs>;
       fhir:Reference.reference [ fhir:value "QuestionnaireResponse/gcs" ];
       fhir:Reference.display [ fhir:value "GCS form results" ]
     ]
  ] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

<http://hl7.org/fhir/QuestionnaireResponse/gcs> a fhir:QuestionnaireResponse .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.