STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationrequest0332.xml

Raw XML (canonical form)

Order for a medication that is intended to be given as a single, once only dose (id = "medrx0332")

<MedicationRequest xmlns="http://hl7.org/fhir">
    <id value="medrx0332"/>
    <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medrx0332</p><p><b>contained</b>: </p><p><b>identifier</b>: 12345689 (OFFICIAL)</p><p><b>definition</b>: <a>ActivityDefinition/example</a></p><p><b>basedOn</b>: <a>CarePlan/gpvisit</a></p><p><b>requisition</b>: 983939393 (OFFICIAL)</p><p><b>status</b>: active</p><p><b>stage</b>: original-order <span>(Details : {[not stated] code 'original-order' = 'original-order)</span></p><p><b>medication</b>: id: med03499; Ceftriaxone sodium 500mg powder for injection solution vial (product)
         <span>(Details : {SNOMED CT code '375860009' = 'Ceftriaxone sodium 500mg powder for injection
           solution vial (product)', given as 'Ceftriaxone sodium 500mg powder for injection solution
           vial (product)'})</span></p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>context</b>: <a>encounter who leads to this prescription</a></p><p><b>dateWritten</b>: 15/01/2015</p><p><b>requester</b>: <a>Patrick Pump</a></p><p><b>dosageInstruction</b>: </p></div></text><contained>
      <Medication>
          <id value="med03499"/>
          <code>
              <coding>
                  <system value="http://snomed.info/sct"/>
                  <code value="375860009"/>
                  <display value="Ceftriaxone sodium 500mg powder for injection solution vial (product)"/>
              </coding>
          </code>
      </Medication>
  </contained>
    <identifier>
        <use value="official"/>
        <system value="http://www.bmc.nl/portal/prescriptions"/>
        <value value="12345689"/>
    </identifier>
    <definition>
        <reference value="ActivityDefinition/example"/>
    </definition>
    <basedOn>
        <reference value="CarePlan/gpvisit"/>
    </basedOn>
    <requisition>
        <use value="official"/>
        <system value="http://www.bmc.nl/portal/prescriptions"/>
        <value value="983939393"/>
    </requisition>
    <status value="active"/>
    <stage>
        <coding>
            <code value="original-order"/>
        </coding>
    </stage>
    <medicationReference> <!--    Linked to a RESOURCE Medication    -->
           <reference value="#med03499"/>
    </medicationReference> 
    <patient> <!--    Linked to the resource patient who needs the medication    -->
        <reference value="Patient/pat1"/>
        <display value="Donald Duck"/>        
    </patient>
    <context> <!--    Linked to a resource Encounter between patient and practitioner   -->
        <reference value="Encounter/f001"/>
        <display value="encounter who leads to this prescription"/>
    </context>
    <dateWritten value="2015-01-15"/>
    <requester> 
        <reference value="Practitioner/f007"/>
        <display value="Patrick Pump"/>
    </requester>
    <dosageInstruction>
        <sequence value="1"/>
        <text value="Administer 500mg IM as a single dose"/>
        <timing>
                <repeat>
                    <count value="1"/>
                </repeat>   
        </timing>
        <route>
            <coding>
                <system value="http://snomed.info/sct"/>
                <code value="255559005"/>
                <display value="Intramuscular (qualifier value)"/>
            </coding>
        </route>
        <doseQuantity>
            <value value="500"/>
            <unit value="mg"/>
            <system value="http://unitsofmeasure.org"/>
            <code value="mg"/> 
        </doseQuantity>
    </dosageInstruction>
</MedicationRequest>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.