This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Dispense for Oxycodone (RxNorm code) - PRN dose with dose range, coded additional instructions and PRN coded pre-condition
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/id/> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/MedicationDispense/meddisp0303> a fhir:MedicationDispense; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "meddisp0303"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: meddisp0303</p><p><b>contained</b>: </p><p><b>status</b>: on-hold</p><p><b>medication</b>: id: med0310; Oxycodone Hydrochloride 5mg oral tablet (Roxicodone <span>(Details : {RxNorm code '1049623' = '1049623', given as 'Oxycodone Hydrochloride 5mg oral tablet (Roxicodone'})</span></p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>dispenser</b>: <a>Rob van den Berk</a></p><p><b>authorizingPrescription</b>: <a>MedicationRequest/medrx0310</a></p><p><b>type</b>: emergency Fill <span>(Details : {http://hl7.org/fhir/ValueSet/v3-ActPharmacySupplyType code 'EF' = 'EF', given as 'emergency Fill'})</span></p><p><b>quantity</b>: 30 TAB<span> (Details: http://hl7.org/fhir/ValueSet/v3-orderableDrugForm code TAB = 'TAB')</span></p><p><b>daysSupply</b>: 10 Day<span> (Details: UCUM code d = 'd')</span></p><p><b>whenPrepared</b>: 15/04/2016 7:14:00 AM</p><p><b>whenHandedOver</b>: 15/04/2016 7:14:00 AM</p><p><b>dosageInstruction</b>: </p></div>" ]; fhir:DomainResource.contained [ a fhir:Medication; fhir:index 0; fhir:Resource.id [ fhir:value "med0310" ]; fhir:Medication.code [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://www.nlm.nih.gov/research/umls/rxnorm" ]; fhir:Coding.code [ fhir:value "1049623" ]; fhir:Coding.display [ fhir:value "Oxycodone Hydrochloride 5mg oral tablet (Roxicodone" ] ] ] ]; fhir:MedicationDispense.status [ fhir:value "on-hold"]; fhir:MedicationDispense.medicationReference [ fhir:Reference.reference [ fhir:value "#med0310" ] ]; fhir:MedicationDispense.patient [ fhir:link <http://hl7.org/fhir/Patient/pat1>; fhir:Reference.reference [ fhir:value "Patient/pat1" ]; fhir:Reference.display [ fhir:value "Donald Duck" ] ]; fhir:MedicationDispense.dispenser [ fhir:link <http://hl7.org/fhir/Practitioner/f006>; fhir:Reference.reference [ fhir:value "Practitioner/f006" ]; fhir:Reference.display [ fhir:value "Rob van den Berk" ] ]; fhir:MedicationDispense.authorizingPrescription [ fhir:index 0; fhir:link <http://hl7.org/fhir/MedicationRequest/medrx0310>; fhir:Reference.reference [ fhir:value "MedicationRequest/medrx0310" ] ]; fhir:MedicationDispense.type [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/ValueSet/v3-ActPharmacySupplyType" ]; fhir:Coding.code [ fhir:value "EF" ]; fhir:Coding.display [ fhir:value "emergency Fill" ] ] ]; fhir:MedicationDispense.quantity [ fhir:Quantity.value [ fhir:value "30"^^xsd:decimal ]; fhir:Quantity.system [ fhir:value "http://hl7.org/fhir/ValueSet/v3-orderableDrugForm" ]; fhir:Quantity.code [ fhir:value "TAB" ] ]; fhir:MedicationDispense.daysSupply [ fhir:Quantity.value [ fhir:value "10"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "Day" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "d" ] ]; fhir:MedicationDispense.whenPrepared [ fhir:value "2016-04-15T07:14:00+05:00"^^xsd:dateTime]; fhir:MedicationDispense.whenHandedOver [ fhir:value "2016-04-15T07:14:00+05:00"^^xsd:dateTime]; fhir:MedicationDispense.dosageInstruction [ fhir:index 0; fhir:DosageInstruction.sequence [ fhir:value "1"^^xsd:int ]; fhir:DosageInstruction.text [ fhir:value "one to two tablets every 4-6 hours as needed for rib pain" ]; fhir:DosageInstruction.additionalInstructions [ fhir:index 0; fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:418914006; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "418914006" ]; fhir:Coding.display [ fhir:value "Warning. May cause drowsiness. If affected do not drive or operate machinery. Avoid alcoholic drink (qualifier value)" ] ] ]; fhir:DosageInstruction.timing [ fhir:Timing.repeat [ fhir:Timing.repeat.frequency [ fhir:value "1"^^xsd:int ]; fhir:Timing.repeat.period [ fhir:value "4"^^xsd:decimal ]; fhir:Timing.repeat.periodMax [ fhir:value "6"^^xsd:decimal ]; fhir:Timing.repeat.periodUnit [ fhir:value "h" ] ] ]; fhir:DosageInstruction.asNeededCodeableConcept [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:297217002; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "297217002" ]; fhir:Coding.display [ fhir:value "Rib Pain (finding)" ] ] ]; fhir:DosageInstruction.route [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:26643006; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "26643006" ]; fhir:Coding.display [ fhir:value "Oral Route" ] ] ]; fhir:DosageInstruction.method [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:concept sct:421521009; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "421521009" ]; fhir:Coding.display [ fhir:value "Swallow - dosing instruction imperative (qualifier value)" ] ] ] ] . <http://hl7.org/fhir/Patient/pat1> a fhir:Patient . <http://hl7.org/fhir/Practitioner/f006> a fhir:Practitioner . <http://hl7.org/fhir/MedicationRequest/medrx0310> a fhir:MedicationRequest . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.