STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Medicationdispense0301.json

Raw JSON (canonical form)

Dispense for IV Antibiotic - in progress - Vancomycin IV (NDC Code) - in-progress

{
  "resourceType": "MedicationDispense",
  "id": "meddisp0301",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: meddisp0301</p><p><b>contained</b>: </p><p><b>status</b>: in-progress</p><p><b>medication</b>: Vancomycin Hydrochloride. Generated Summary: id: med0301; Vancomycin Hydrochloride (VANCOMYCIN HYDROCHLORIDE) <span>(Details : {http://hl7.org/fhir/sid/ndc code '0069-2587-10' = '0069-2587-10', given as 'Vancomycin Hydrochloride (VANCOMYCIN HYDROCHLORIDE)'})</span></p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>supportingInformation</b>: <a>Condition/f203</a></p><p><b>dispenser</b>: <a>Rob van den Berk</a></p><p><b>dispensingOrganization</b>: <a>Organization/f201</a></p><p><b>authorizingPrescription</b>: <a>MedicationRequest/medrx0318</a></p><p><b>type</b>: emergency Fill <span>(Details : {http://hl7.org/fhir/ValueSet/v3-ActPharmacySupplyType code 'EF' = 'EF', given as 'emergency Fill'})</span></p><p><b>quantity</b>: 12 Vial<span> (Details: http://hl7.org/fhir/ValueSet/v3-orderableDrugForm code Vial = 'Vial')</span></p><p><b>daysSupply</b>: 3 Day<span> (Details: UCUM code d = 'd')</span></p><p><b>whenPrepared</b>: 15/01/2015 9:20:00 PM</p><p><b>destination</b>: <a>Location/ph</a></p><p><b>receiver</b>: <a>Donald Duck</a></p><p><b>dosageInstruction</b>: </p></div>"
  },
  "contained": [
    {
      "resourceType": "Medication",
      "id": "med0301",
      "code": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/sid/ndc",
            "code": "0069-2587-10",
            "display": "Vancomycin Hydrochloride (VANCOMYCIN HYDROCHLORIDE)"
          }
        ]
      }
    }
  ],
  "status": "in-progress",
  "medicationReference": {
    "reference": "#med0301",
    "display": "Vancomycin Hydrochloride"
  },
  "patient": {
    "reference": "Patient/pat1",
    "display": "Donald Duck"
  },
  "supportingInformation": [
    {
      "reference": "Condition/f203"
    }
  ],
  "dispenser": {
    "reference": "Practitioner/f006",
    "display": "Rob van den Berk"
  },
  "dispensingOrganization": {
    "reference": "Organization/f201"
  },
  "authorizingPrescription": [
    {
      "reference": "MedicationRequest/medrx0318"
    }
  ],
  "type": {
    "coding": [
      {
        "system": "http://hl7.org/fhir/ValueSet/v3-ActPharmacySupplyType",
        "code": "EF",
        "display": "emergency Fill"
      }
    ]
  },
  "quantity": {
    "value": 12,
    "unit": "Vial",
    "system": "http://hl7.org/fhir/ValueSet/v3-orderableDrugForm",
    "code": "Vial"
  },
  "daysSupply": {
    "value": 3,
    "unit": "Day",
    "system": "http://unitsofmeasure.org",
    "code": "d"
  },
  "whenPrepared": "2015-01-15T10:20:00Z",
  "destination": {
    "reference": "Location/ph"
  },
  "receiver": [
    {
      "reference": "Patient/pat1",
      "display": "Donald Duck"
    }
  ],
  "dosageInstruction": [
    {
      "sequence": 1,
      "text": "500mg IV q6h x 3 days",
      "timing": {
        "repeat": {
          "frequency": 1,
          "period": 6,
          "periodUnit": "h"
        }
      },
      "route": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "255560000",
            "display": "Intravenous"
          }
        ]
      },
      "method": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "420620005",
            "display": "Push - dosing instruction imperative (qualifier value)"
          }
        ]
      },
      "doseQuantity": {
        "value": 500,
        "unit": "mg",
        "system": "http://unitsofmeasure.org",
        "code": "mg"
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.