STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Diagnosticreport-example-ultrasound.ttl

Raw Turtle, JSON-LD

Abdominal Ultrasound example

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/id/> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/DiagnosticReport/ultrasound> a fhir:DiagnosticReport;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "ultrasound"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: ultrasound</p><p><b>status</b>: final</p><p><b>category</b>: Radiology <span>(Details : {SNOMED CT code '394914008' = 'Radiology - specialty (qualifier value)', given as 'Radiology'}; {http://hl7.org/fhir/v2/0074 code 'RAD' = 'Radiology)</span></p><p><b>code</b>: Abdominal Ultrasound <span>(Details : {SNOMED CT code '45036003' = 'Ultrasonography of abdomen (procedure)', given as 'Ultrasonography of abdomen'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 01/12/2012 12:00:00 PM</p><p><b>issued</b>: 01/12/2012 12:00:00 PM</p><p><b>performer</b>: <a>Practitioner/example</a></p><h3>Images</h3><table><tr><td>-</td><td><b>Comment</b></td><td><b>Link</b></td></tr><tr><td>*</td><td>A comment about the image</td><td><a>WADO example image</a></td></tr></table><p><b>conclusion</b>: Unremarkable study</p></div>"
  ];
  fhir:DiagnosticReport.status [ fhir:value "final"];
  fhir:DiagnosticReport.category [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:concept sct:394914008;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "394914008" ];
       fhir:Coding.display [ fhir:value "Radiology" ]
     ], [
       fhir:index 1;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0074" ];
       fhir:Coding.code [ fhir:value "RAD" ]
     ]
  ];
  fhir:DiagnosticReport.code [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:concept sct:45036003;
       fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
       fhir:Coding.code [ fhir:value "45036003" ];
       fhir:Coding.display [ fhir:value "Ultrasonography of abdomen" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "Abdominal Ultrasound" ]
  ];
  fhir:DiagnosticReport.subject [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ];
  fhir:DiagnosticReport.effectiveDateTime [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime];
  fhir:DiagnosticReport.issued [ fhir:value "2012-12-01T12:00:00+01:00"^^xsd:dateTime];
  fhir:DiagnosticReport.performer [
     fhir:index 0;
     fhir:link <http://hl7.org/fhir/Practitioner/example>;
     fhir:Reference.reference [ fhir:value "Practitioner/example" ]
  ];
  fhir:DiagnosticReport.image [
     fhir:index 0;
     fhir:DiagnosticReport.image.comment [ fhir:value "A comment about the image" ];
     fhir:DiagnosticReport.image.link [
       fhir:link <http://hl7.org/fhir/Media/1.2.840.11361907579238403408700.3.0.14.19970327150033>;
       fhir:Reference.reference [ fhir:value "Media/1.2.840.11361907579238403408700.3.0.14.19970327150033" ];
       fhir:Reference.display [ fhir:value "WADO example image" ]
     ]
  ];
  fhir:DiagnosticReport.conclusion [ fhir:value "Unremarkable study"] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

<http://hl7.org/fhir/Practitioner/example> a fhir:Practitioner .

<http://hl7.org/fhir/Media/1.2.840.11361907579238403408700.3.0.14.19970327150033> a fhir:Media .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.