STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R3

Device-example-udi4.ttl

Raw Turtle, JSON-LD

Blood Bag UDI example ICCBBA Format

@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir/Device/example-udi4> a fhir:Device;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "example-udi4"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ];
     fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: example-udi4</p><p><b>udiCarrier</b>: Universal Device Identifier = =)1TE123456A&amp;)RZ12345678</p><p><b>status</b>: not-available</p><p><b>type</b>: DI = 1TE123456A <span>(Details : {http://hl7.org/fhir/NamingSystem/iccbba-blood-di code '1TE123456A' = '1TE123456A)</span></p><p><b>lotNumber</b>: RZ12345678</p><p><b>manufacturer</b>: GlobalMed, Inc</p><p><b>patient</b>: <a>Patient/example</a></p></div>"
  ];
  fhir:Device.udiCarrier [
     fhir:Identifier.type [
       fhir:CodeableConcept.coding [
         fhir:index 0;
         fhir:Coding.system [ fhir:value "http://hl7.org/fhir/identifier-type" ];
         fhir:Coding.code [ fhir:value "UDI" ]
       ]
     ];
     fhir:Identifier.system [ fhir:value "http://hl7.org/fhir/NamingSystem/fda-udi" ];
     fhir:Identifier.value [ fhir:value "=)1TE123456A&)RZ12345678" ]
  ];
  fhir:Device.status [ fhir:value "not-available"];
  fhir:Device.type [
     fhir:CodeableConcept.coding [
       fhir:index 0;
       fhir:Coding.system [ fhir:value "http://hl7.org/fhir/NamingSystem/iccbba-blood-di" ];
       fhir:Coding.code [ fhir:value "1TE123456A" ]
     ];
     fhir:CodeableConcept.text [ fhir:value "DI = 1TE123456A" ]
  ];
  fhir:Device.lotNumber [ fhir:value "RZ12345678"];
  fhir:Device.manufacturer [ fhir:value "GlobalMed, Inc"];
  fhir:Device.patient [
     fhir:link <http://hl7.org/fhir/Patient/example>;
     fhir:Reference.reference [ fhir:value "Patient/example" ]
  ] .

<http://hl7.org/fhir/Patient/example> a fhir:Patient .

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.