STU3 Candidate

This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R3 R2

Dataelement-labtestmaster-example.xml

Raw XML (canonical form)

Prothrombin time for lab test master file (id = "prothrombin")

<DataElement xmlns="http://hl7.org/fhir">
  <id value="prothrombin"/>
  <text><status value="generated"/><div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: prothrombin</p><p><b>identifier</b>: Prothrombin Time, PT = 11</p><p><b>status</b>: active</p><p><b>name</b>: Prothrombin Time</p><h3>Mappings</h3><table><tr><td>-</td><td><b>Identity</b></td><td><b>Uri</b></td><td><b>Name</b></td><td><b>Comment</b></td></tr><tr><td>*</td><td>loinc</td><td><a>http://loinc.org/</a></td><td>LOINC</td><td>Version 2.48 or later</td></tr></table><p><b>element</b>: todo-bundle</p></div></text><identifier>
    <type>
      <text value="Prothrombin Time, PT"/>
    </type>
    <system value="http://www.CenturyHospital/Laboratory/DirectoryofServices"/>
    <value value="11"/>
    <period>
      <start value="2011-05-19"/>
    </period>
    <assigner>
      <display value="Century Hospital Laboratory"/>
    </assigner>
  </identifier>
  <status value="active"/>
  <name value="Prothrombin Time"/>
  <mapping>
    <identity value="loinc"/>
    <uri value="http://loinc.org/"/>
    <name value="LOINC"/>
    <comment value="Version 2.48 or later"/>
  </mapping>
  <element>
    <extension url="http://hl7.org/fhir/StructureDefinition/elementdefinition-allowedUnits">
      <valueCodeableConcept>
        <coding>
          <system value="http://unitsofmeasure.org"/>
          <version value="1.9"/>
          <code value="s"/>
          <display value="second"/>
          <userSelected value="true"/>
        </coding>
        <text value="second"/>
      </valueCodeableConcept>
    </extension>
    <path value="prothrombin"/>
    <definition value="The PT test evaluates the extrinsic and common pathways of the coagulation cascade."/>
    <comments value="Used to screen the integrity of the extrinsic and common pathways of coagulation and to
     monitor warfarin anticoagulation. "/>
    <requirements value="This test is orderable. A plasma specimen in a 3.2% sodium citrate blue top tube is required."/>
    <alias value="Protime, PT"/>
    <type>
      <code value="decimal"/>
    </type>
    <!--     Is this the FHIR datatype for the observation? ( ie the datatype when ordering the
     test) or the Result? ( ie. numeric, codeable concept or text for lab tests )    -->
    <example>
      <label value="Simple"/>
      <valueDecimal value="10.0"/>
    </example>
    <!--     Is this the an example result like "10.0"  for the observation/dataelement?     -->
    <mapping>
      <identity value="loinc"/>
      <map value="5964-2"/>
    </mapping>
  </element>
</DataElement>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.