This page is part of the FHIR Specification (v1.8.0: STU 3 Draft). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
. Page versions: R5 R4B R4 R3
General Condition Example
{
"resourceType": "CapabilityStatement",
"id": "example",
"text": {
"status": "generated",
"div": "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n \n <p>The EHR Server supports the following transactions for the resource Person: read, vread, \n update, history, search(name,gender), create and updates.</p>\n \n <p>The EHR System supports the following message: admin-notify::Person.</p>\n \n <p>The EHR Application has a \n <a href=\"http://fhir.hl7.org/base/Profilebc054d23-75e1-4dc6-aca5-838b6b1ac81d/_history/b5fdd9fc-b021-4ea1-911a-721a60663796\">general document profile</a>.\n </p>\n \n </div>"
},
"url": "68D043B5-9ECF-4559-A57A-396E0D452311",
"version": "20130510",
"name": "ACME EHR capability statement",
"status": "draft",
"experimental": true,
"date": "2012-01-04",
"publisher": "ACME Corporation",
"contact": [
{
"name": "System Administrator",
"telecom": [
{
"system": "email",
"value": "wile@acme.org"
}
]
}
],
"description": "This is the FHIR capability statement for the main EHR at ACME for the private interface - it does not describe the public interface",
"purpose": "Main EHR capability statement, published for contracting and operational support",
"copyright": "Copyright © Acme Healthcare and GoodCorp EHR Systems",
"kind": "instance",
"software": {
"name": "EHR",
"version": "0.00.020.2134",
"releaseDate": "2012-01-04"
},
"implementation": {
"description": "main EHR at ACME",
"url": "http://10.2.3.4/fhir"
},
"fhirVersion": "1.0.0",
"acceptUnknown": "both",
"format": [
"xml",
"json"
],
"rest": [
{
"mode": "server",
"documentation": "Main FHIR endpoint for acem health",
"security": {
"cors": true,
"service": [
{
"coding": [
{
"system": "http://hl7.org/fhir/restful-security-service",
"code": "SMART-on-FHIR"
}
]
}
],
"description": "See Smart on FHIR documentation",
"certificate": [
{
"type": "application/jwt",
"blob": "IHRoaXMgYmxvYiBpcyBub3QgdmFsaWQ="
}
]
},
"resource": [
{
"type": "Patient",
"profile": {
"reference": "http://fhir.hl7.org/base/StructureDefinition/7896271d-57f6-4231-89dc-dcc91eab2416"
},
"interaction": [
{
"code": "read"
},
{
"code": "vread",
"documentation": "Only supported for patient records since 12-Dec 2012"
},
{
"code": "update"
},
{
"code": "history-instance"
},
{
"code": "create"
},
{
"code": "history-type"
}
],
"versioning": "versioned-update",
"readHistory": true,
"updateCreate": false,
"conditionalCreate": true,
"conditionalUpdate": false,
"conditionalDelete": "not-supported",
"searchInclude": [
"Organization"
],
"searchRevInclude": [
"Person"
],
"searchParam": [
{
"name": "identifier",
"definition": "http://hl7.org/fhir/SearchParameter/Patient-identifier",
"type": "token",
"documentation": "Only supports search by institution MRN"
},
{
"name": "careprovider",
"definition": "http://hl7.org/fhir/SearchParameter/Patient-careprovider",
"type": "reference"
}
]
}
],
"interaction": [
{
"code": "transaction"
},
{
"code": "history-system"
}
],
"compartment": [
"http://hl7.org/fhir/compartment/Patient"
]
}
],
"messaging": [
{
"endpoint": [
{
"protocol": {
"system": "http://hl7.org/fhir/message-transport",
"code": "mllp"
},
"address": "mllp:10.1.1.10:9234"
}
],
"reliableCache": 30,
"documentation": "ADT A08 equivalent for external system notifications",
"event": [
{
"code": {
"system": "http://hl7.org/fhir/message-type",
"code": "admin-notify"
},
"category": "Consequence",
"mode": "receiver",
"focus": "Patient",
"request": {
"reference": "StructureDefinition/daf-patient"
},
"response": {
"reference": "StructureDefinition/MessageHeader"
},
"documentation": "Notification of an update to a patient resource. changing the links is not supported"
}
]
}
],
"document": [
{
"mode": "consumer",
"documentation": "Basic rules for all documents in the EHR system",
"profile": {
"reference": "http://fhir.hl7.org/base/Profilebc054d23-75e1-4dc6-aca5-838b6b1ac81d/_history/b5fdd9fc-b021-4ea1-911a-721a60663796"
}
}
]
}
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.