STU 3 Ballot

This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Medicationorder0319.json

Raw JSON (canonical form)

Order for Intravenous Antibiotic with a Dosage Rate - Piperacillin - completed with reason code

{
  "resourceType": "MedicationOrder",
  "id": "medrx0319",
  "text": {
    "status": "generated",
    "div": "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: medrx0319</p><p><b>contained</b>: </p><p><b>identifier</b>: 12345689 (OFFICIAL)</p><p><b>status</b>: completed</p><p><b>medication</b>: Piperacillin/Tazobactam 4.5gm. Generated Summary: id: med0302; Zosyn (piperacillin/tazobactam) 4.5gm injection <span>(Details : {http://hl7.org/fhir/sid/ndc code '0206-8862-02' = '??', given as 'Zosyn (piperacillin/tazobactam) 4.5gm injection'})</span></p><p><b>patient</b>: <a>Donald Duck</a></p><p><b>dateWritten</b>: 15/01/2015</p><p><b>prescriber</b>: <a>Patrick Pump</a></p><p><b>reasonCode</b>: Community acquired pneumonia (disorder) <span>(Details : {SNOMED CT code '385093006' = 'Community acquired pneumonia (disorder)', given as 'Community acquired pneumonia (disorder)'})</span></p><h3>DosageInstructions</h3><table><tr><td>-</td><td><b>Text</b></td><td><b>Timing</b></td><td><b>Route</b></td><td><b>Dose[x]</b></td><td><b>Rate[x]</b></td></tr><tr><td>*</td><td>4.5 grams in D5W 250 ml. IV every 6 hours.Infuse over 30 min at 8L/min </td><td>Do Once per 6 hours</td><td>Intravenous route (qualifier value) <span>(Details : {SNOMED CT code '47625008' = 'Intravenous route (qualifier value)', given as 'Intravenous route (qualifier value)'})</span></td><td>4.5 g<span> (Details: http://unitsofmeasure.org code g = 'g')</span></td><td>8 ml<span> (Details: http://unitsofmeasure.org code ml = 'ml')</span>/1 min<span> (Details: http://unitsofmeasure.org code min = 'min')</span></td></tr></table></div>"
  },
  "contained": [
    {
      "resourceType": "Medication",
      "id": "med0302",
      "code": {
        "coding": [
          {
            "system": "http://hl7.org/fhir/sid/ndc",
            "code": "0206-8862-02",
            "display": "Zosyn (piperacillin/tazobactam) 4.5gm injection"
          }
        ]
      }
    }
  ],
  "identifier": [
    {
      "use": "official",
      "system": "http://www.bmc.nl/portal/prescriptions",
      "value": "12345689"
    }
  ],
  "status": "completed",
  "medicationReference": {
    "reference": "#med0302",
    "display": "Piperacillin/Tazobactam 4.5gm"
  },
  "patient": {
    "reference": "Patient/pat1",
    "display": "Donald Duck"
  },
  "dateWritten": "2015-01-15",
  "prescriber": {
    "reference": "Practitioner/f007",
    "display": "Patrick Pump"
  },
  "reasonCode": [
    {
      "coding": [
        {
          "system": "http://snomed.info/sct",
          "code": "385093006",
          "display": "Community acquired pneumonia (disorder)"
        }
      ]
    }
  ],
  "dosageInstruction": [
    {
      "text": "4.5 grams in D5W 250 ml. IV every 6 hours.Infuse over 30 min at 8L/min ",
      "timing": {
        "repeat": {
          "frequency": 1,
          "period": 6,
          "periodUnit": "h"
        }
      },
      "route": {
        "coding": [
          {
            "system": "http://snomed.info/sct",
            "code": "47625008",
            "display": "Intravenous route (qualifier value)"
          }
        ]
      },
      "doseQuantity": {
        "value": 4.5,
        "unit": "g",
        "system": "http://unitsofmeasure.org",
        "code": "g"
      },
      "rateRatio": {
        "numerator": {
          "value": 8,
          "system": "http://unitsofmeasure.org",
          "code": "ml"
        },
        "denominator": {
          "value": 1,
          "system": "http://unitsofmeasure.org",
          "code": "min"
        }
      }
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.