STU 3 Candidate

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3

Valueset-observation-vitalsignresult.json

Raw JSON (canonical form)

Definition for Value SetVital Signs

{
  "resourceType": "ValueSet",
  "id": "observation-vitalsignresult",
  "meta": {
    "lastUpdated": "2016-03-31T08:01:25.570+11:00",
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition"
    ]
  },
  "text": {
    "status": "generated",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/valueset-oid",
      "valueUri": "urn:oid:2.16.840.1.113883.3.88.12.80.62"
    }
  ],
  "url": "http://hl7.org/fhir/ValueSet/observation-vitalsignresult",
  "version": "1.4.0",
  "name": "Vital Signs",
  "status": "active",
  "experimental": true,
  "publisher": "FHIR project team",
  "contact": [
    {
      "telecom": [
        {
          "system": "other",
          "value": "http://hl7.org/fhir"
        }
      ]
    }
  ],
  "date": "2016-03-31T08:01:25+11:00",
  "description": "This value set indicates the allowed vital sign result types.   The concept Vitals Signs Panel (8716-3) is a grouping structure for a set of vital signs and includes related links (with type=has-member) to the Observations in this set (e.g. respiratory rate, heart rate, BP).  The Blood pressure systolic and diastolic (55284-4) is used to group the component observations Systolic blood pressure (8480-6) and Diastolic blood pressure (8462-4).",
  "_description": {
    "fhir_comments": [
      "  Value Set: HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC\n\t\tCode System(s)  LOINC 2.16.840.1.113883.6.1  Note the base resource does not allow for display terms -Gforge ticket Item and expansion doesn;t allow for time less than a seconde for instantiation so assume is to be machine generated.  "
    ]
  },
  "copyright": "This content from LOINC® is copyright © 1995 Regenstrief Institute, Inc. and the LOINC Committee, and available at no cost under the license at http://loinc.org/terms-of-use",
  "compose": {
    "include": [
      {
        "system": "http://loinc.org",
        "concept": [
          {
            "code": "8716-3"
          },
          {
            "code": "9279-1"
          },
          {
            "code": "8867-4"
          },
          {
            "code": "2708-6"
          },
          {
            "code": "8310-5"
          },
          {
            "code": "8302-2"
          },
          {
            "fhir_comments": [
              "\t\n\t\t\t<concept>\n\t\t\t\t<code value=\"8306-3\"/>\n\t\t\t</concept>\t\n\n\t\t\t<concept>\n\t\t\t\t<code value=\"8287-5\"/>\n\t\t\t</concept>\n"
            ],
            "code": "29463-7"
          },
          {
            "code": "39156-5"
          },
          {
            "fhir_comments": [
              "\n\t\t\t<concept>\n\t\t\t\t<code value=\"3140-1\"/>\n\t\t\t</concept>\n\t"
            ],
            "code": "55284-4"
          },
          {
            "code": "8480-6"
          },
          {
            "code": "8462-4"
          },
          {
            "code": "8478-0"
          }
        ]
      }
    ]
  }
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.