This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions
Definition for Value SetReasons for rejecting goal codes
{ "resourceType": "ValueSet", "id": "qicore-goal-reason-rejected", "meta": { "lastUpdated": "2016-03-31T08:01:25.570+11:00", "profile": [ "http://hl7.org/fhir/StructureDefinition/valueset-shareable-definition" ] }, "text": { "status": "generated", "div": "<div>!-- Snipped for Brevity --></div>" }, "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-oid", "valueUri": "urn:oid:2.16.840.1.113883.4.642.2.623" } ], "url": "http://hl7.org/fhir/ValueSet/qicore-goal-reason-rejected", "version": "1.4.0", "name": "Reasons for rejecting goal codes", "status": "draft", "experimental": true, "publisher": "HL7 Clinical Quality Information (CQI) Work Group", "contact": [ { "telecom": [ { "system": "other", "value": "http://www.hl7.org/Special/committees/cqi" } ] } ], "date": "2016-03-31T08:01:25+11:00", "description": "The value set to instantiate this attribute should be drawn from a terminologically robust code system that consists of or contains concepts to support the goal process, in particular the process and reasons for rejecting a goal. This value set is provided as a suggestive example.", "copyright": "This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement.", "compose": { "include": [ { "system": "http://hl7.org/fhir/v3/ActReason", "concept": [ { "fhir_comments": [ " todo: this is a starting list. needs more reason codes ", " _SchedulingActReason ", " Unexpected Block (of Schedule) " ], "code": "BLK" }, { "fhir_comments": [ " Patient Deceased " ], "code": "DEC" }, { "fhir_comments": [ " No Financial Backing " ], "code": "FIN" }, { "fhir_comments": [ " Medical Status Altered " ], "code": "MED" }, { "fhir_comments": [ " _ControlActNullificationReasonCode ", " altered decision " ], "code": "ALTD" } ] }, { "system": "http://snomed.info/sct", "filter": [ { "property": "concept", "op": "is-a", "value": "410521004", "_value": { "fhir_comments": [ " Pre-starting action status / Not to be done codes " ] } } ] } ] } }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.