This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Specimen Reject Example
@prefix fhir: <http://hl7.org/fhir/> . @prefix loinc: <http://loinc.org/owl#> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix sct: <http://snomed.info/sct/> . @prefix xs: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir//Observation/unsat> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "unsat"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ] ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.use [ fhir:value "official" ]; fhir:Identifier.system [ fhir:value "http://www.bmc.nl/zorgportal/identifiers/observations" ]; fhir:Identifier.value [ fhir:value "6323" ] ]; fhir:Observation.status [ fhir:value "cancelled"]; fhir:Observation.code [ a loinc:15074-8; fhir:CodeableConcept.coding [ fhir:index 0; a loinc:15074-8; fhir:Coding.system [ fhir:value "http://loinc.org" ]; fhir:Coding.code [ fhir:value "15074-8" ]; fhir:Coding.display [ fhir:value "Glucose [Moles/volume] in Blood" ] ] ]; fhir:Observation.subjectReference [ fhir:reference <http://hl7.org/fhir/Patient/f001>; fhir:Reference.reference [ fhir:value "Patient/f001" ]; fhir:Reference.display [ fhir:value "P. van de Heuvel" ] ]; fhir:Observation.effectivePeriod [ fhir:Period.start [ fhir:value "2013-04-02T09:30:10+01:00"^^xs:dateTime ]; fhir:Period.end [ fhir:value "2013-04-05T09:30:10+01:00"^^xs:dateTime ] ]; fhir:Observation.issued [ fhir:value "2013-04-03T15:30:10+01:00"^^xs:dateTime]; fhir:Observation.performerReference [ fhir:index 0; fhir:reference <http://hl7.org/fhir/Practitioner/f005>; fhir:Reference.reference [ fhir:value "Practitioner/f005" ]; fhir:Reference.display [ fhir:value "A. Langeveld" ] ]; fhir:Observation.dataAbsentReason [ a sct:125154007; fhir:CodeableConcept.coding [ fhir:index 0; a sct:125154007; fhir:Coding.system [ fhir:value "http://snomed.info/sct" ]; fhir:Coding.code [ fhir:value "125154007" ]; fhir:Coding.display [ fhir:value "Specimen unsatisfactory for evaluation" ] ] ]; fhir:Observation.comment [ fhir:value "Tube broken in transit and sample leaked"]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "3.1"^^xs:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "6.2"^^xs:decimal ]; fhir:Quantity.unit [ fhir:value "mmol/l" ]; fhir:Quantity.system [ fhir:value "http://unitsofmeasure.org" ]; fhir:Quantity.code [ fhir:value "mmol/L" ] ] ]. # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.