STU 3 Candidate

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions

Diagnosticorder-example-di.ttl

Raw Turtle, JSON-LD

CT Scan order

@prefix fhir: <http://hl7.org/fhir/> .
@prefix loinc: <http://loinc.org/owl#> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix sct: <http://snomed.info/sct/> .
@prefix xs: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/fhir//DiagnosticOrder/di> a fhir:DiagnosticOrder;
  fhir:nodeRole fhir:treeRoot;
  fhir:Resource.id [ fhir:value "di"];
  fhir:DomainResource.text [
     fhir:Narrative.status [ fhir:value "generated" ]
  ];
  fhir:DiagnosticOrder.status [ fhir:value "requested"];
  fhir:DiagnosticOrder.subjectReference [
     fhir:reference <http://hl7.org/fhir/Patient/dicom>;
     fhir:Reference.reference [ fhir:value "Patient/dicom" ]
  ];
  fhir:DiagnosticOrder.orderer [
     fhir:reference <http://hl7.org/fhir/Practitioner/example>;
     fhir:Reference.reference [ fhir:value "Practitioner/example" ];
     fhir:Reference.display [ fhir:value "Dr. Adam Careful" ]
  ];
  fhir:DiagnosticOrder.reason [
     fhir:index 0;
     fhir:CodeableConcept.text [ fhir:value "Check for metastatic disease" ]
  ];
  fhir:DiagnosticOrder.event [
     fhir:index 0;
     fhir:DiagnosticOrder.event.status [ fhir:value "requested" ];
     fhir:DiagnosticOrder.event.dateTime [ fhir:value "2013-05-08T09:33:27+07:00"^^xs:dateTime ]
  ];
  fhir:DiagnosticOrder.item [
     fhir:index 0;
     fhir:DiagnosticOrder.item.code [
       a loinc:24627-2;
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a loinc:24627-2;
         fhir:Coding.system [ fhir:value "http://loinc.org" ];
         fhir:Coding.code [ fhir:value "24627-2" ]       ];
       fhir:CodeableConcept.text [ fhir:value "Chest CT" ]     ];
     fhir:DiagnosticOrder.item.bodySite [
       a sct:51185008;
       fhir:CodeableConcept.coding [
         fhir:index 0;
         a sct:51185008;
         fhir:Coding.system [ fhir:value "http://snomed.info/sct" ];
         fhir:Coding.code [ fhir:value "51185008" ];
         fhir:Coding.display [ fhir:value "Thoracic structure" ]       ]     ]
  ].

# -------------------------------------------------------------------------------------


Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.