This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R3 R2
Prothrombin time for lab test master file
{ "resourceType": "DataElement", "id": "prothrombin", "text": { "status": "generated", "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: prothrombin</p><p><b>identifier</b>: Prothrombin Time, PT = 11</p><p><b>status</b>: active</p><p><b>name</b>: Prothrombin Time</p><h3>Mappings</h3><table><tr><td>-</td><td><b>Identity</b></td><td><b>Uri</b></td><td><b>Name</b></td><td><b>Comment</b></td></tr><tr><td>*</td><td>loinc</td><td><a>http://loinc.org/</a></td><td>LOINC</td><td>Version 2.48 or later</td></tr></table><p><b>element</b>: todo-bundle</p></div>" }, "identifier": [ { "type": { "text": "Prothrombin Time, PT" }, "system": "http://www.CenturyHospital/Laboratory/DirectoryofServices", "value": "11", "period": { "start": "2011-05-19" }, "assigner": { "display": "Century Hospital Laboratory" } } ], "status": "active", "name": "Prothrombin Time", "mapping": [ { "identity": "loinc", "uri": "http://loinc.org/", "name": "LOINC", "comment": "Version 2.48 or later" } ], "element": [ { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-allowedUnits", "valueCodeableConcept": { "coding": [ { "system": "http://unitsofmeasure.org", "version": "1.9", "code": "s", "display": "second", "userSelected": true } ], "text": "second" } } ], "path": "prothrombin", "definition": "The PT test evaluates the extrinsic and common pathways of the coagulation cascade.", "comments": "Used to screen the integrity of the extrinsic and common pathways of coagulation and to monitor warfarin anticoagulation. ", "requirements": "This test is orderable. A plasma specimen in a 3.2% sodium citrate blue top tube is required.", "alias": [ "Protime, PT" ], "type": [ { "code": "decimal" } ], "exampleDecimal": 10.0, "_exampleDecimal": { "fhir_comments": [ " Is this the FHIR datatype for the observation? ( ie the datatype when ordering the test) or the Result? ( ie. numeric, codeable concept or text for lab tests ) " ] }, "mapping": [ { "fhir_comments": [ " Is this the an example result like \"10.0\" for the observation/dataelement? " ], "identity": "loinc", "map": "5964-2" } ] } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.