STU 3 Candidate

This page is part of the FHIR Specification (v1.4.0: STU 3 Ballot 3). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R3 R2

Dataelement-labtestmaster-example.json

Raw JSON (canonical form)

Prothrombin time for lab test master file

{
  "resourceType": "DataElement",
  "id": "prothrombin",
  "text": {
    "status": "generated",
    "div": "<div><p><b>Generated Narrative with Details</b></p><p><b>id</b>: prothrombin</p><p><b>identifier</b>: Prothrombin Time, PT = 11</p><p><b>status</b>: active</p><p><b>name</b>: Prothrombin Time</p><h3>Mappings</h3><table><tr><td>-</td><td><b>Identity</b></td><td><b>Uri</b></td><td><b>Name</b></td><td><b>Comment</b></td></tr><tr><td>*</td><td>loinc</td><td><a>http://loinc.org/</a></td><td>LOINC</td><td>Version 2.48 or later</td></tr></table><p><b>element</b>: todo-bundle</p></div>"
  },
  "identifier": [
    {
      "type": {
        "text": "Prothrombin Time, PT"
      },
      "system": "http://www.CenturyHospital/Laboratory/DirectoryofServices",
      "value": "11",
      "period": {
        "start": "2011-05-19"
      },
      "assigner": {
        "display": "Century Hospital Laboratory"
      }
    }
  ],
  "status": "active",
  "name": "Prothrombin Time",
  "mapping": [
    {
      "identity": "loinc",
      "uri": "http://loinc.org/",
      "name": "LOINC",
      "comment": "Version 2.48 or later"
    }
  ],
  "element": [
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/elementdefinition-allowedUnits",
          "valueCodeableConcept": {
            "coding": [
              {
                "system": "http://unitsofmeasure.org",
                "version": "1.9",
                "code": "s",
                "display": "second",
                "userSelected": true
              }
            ],
            "text": "second"
          }
        }
      ],
      "path": "prothrombin",
      "definition": "The PT test evaluates the extrinsic and common pathways of the coagulation cascade.",
      "comments": "Used to screen the integrity of the extrinsic and common pathways of coagulation and to monitor warfarin anticoagulation. ",
      "requirements": "This test is orderable. A plasma specimen in a 3.2% sodium citrate blue top tube is required.",
      "alias": [
        "Protime, PT"
      ],
      "type": [
        {
          "code": "decimal"
        }
      ],
      "exampleDecimal": 10.0,
      "_exampleDecimal": {
        "fhir_comments": [
          "    Is this the FHIR datatype for the observation? ( ie the datatype when ordering the test) or the Result? ( ie. numeric, codeable concept or text for lab tests )   "
        ]
      },
      "mapping": [
        {
          "fhir_comments": [
            "    Is this the an example result like \"10.0\"  for the observation/dataelement?    "
          ],
          "identity": "loinc",
          "map": "5964-2"
        }
      ]
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.