This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3
FHIR Value set/code system definition for HL7 v2 table 0702 ( Cycle Type)
{ "resourceType": "CodeSystem", "id": "v2-0702", "meta": { "profile": [ "http://hl7.org/fhir/StructureDefinition/codesystem-shareable-definition" ] }, "text": { "status": "additional", "div": "<div>!-- Snipped for Brevity --></div>" }, "url": "http://hl7.org/fhir/v2/0702", "identifier": { "system": "urn:ietf:rfc:3986", "value": "urn:oid:2.16.840.1.133883.18.387" }, "version": "2.8.2", "name": "v2 Cycle Type", "status": "active", "experimental": true, "publisher": "HL7, Inc", "contact": [ { "telecom": [ { "system": "other", "value": "http://hl7.org" } ] } ], "description": "FHIR Value set/code system definition for HL7 v2 table 0702 ( Cycle Type)", "caseSensitive": false, "valueSet": "http://hl7.org/fhir/ValueSet/v2-0702", "content": "complete", "concept": [ { "code": "2RS", "display": "Second Rinse" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "Special Wash cycle" } ], "code": "ANR", "display": "Anesthesia/Respiratory" }, { "code": "BDP", "display": "Bedpans" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A Bowie-Dick test cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum." } ], "code": "BWD", "display": "Bowie-Dick Test" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A chemical wash cycle." } ], "code": "CMW", "display": "Chemical Wash" }, { "code": "COD", "display": "Code" }, { "code": "CRT", "display": "Cart Wash" }, { "code": "DEC", "display": "Decontamination" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A dart cycle is a special cycle used to test the integrity of the sterilizer chamber to hold a vacuum." } ], "code": "DRT", "display": "Dart" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A dart warm-up cycle is used to bring the sterilizer chamber up to operating temperature in order to run a dart test cycle." } ], "code": "DRW", "display": "Dart Warm-up Cycle" }, { "code": "EOH", "display": "EO High Temperature" }, { "code": "EOL", "display": "EO Low Temperature" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "An express cycle is similar to a flash cycle but the supply item is wrapped." } ], "code": "EXP", "display": "Express" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "Used to quickly sterilize instruments that were dropped during surgery." } ], "code": "FLS", "display": "Flash" }, { "code": "GLS", "display": "Glassware" }, { "code": "GNP", "display": "Gen. Purpose" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A gravity cycle is executed at atmospheric pressure." } ], "code": "GRV", "display": "Gravity" }, { "code": "GTL", "display": "Gentle" }, { "code": "ISO", "display": "Isothermal" }, { "code": "IST", "display": "Instrument Wash" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A leak test cycle tests the integrity of the sterilizer chamber to hold a vacuum over a specific period of time." } ], "code": "LKT", "display": "Leak Test" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A cycle specific to sterilizing liquids." } ], "code": "LQD", "display": "Liquid" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "Any Optional Wash cycle" } ], "code": "OPW", "display": "Optional Wash" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A peracetic acid cycle." } ], "code": "PEA", "display": "Peracetic Acid" }, { "code": "PLA", "display": "Plastic Goods Wash" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A prevac cycle is vacuum assisted." } ], "code": "PRV", "display": "Prevac" }, { "code": "RNS", "display": "Rinse" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "An SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is wrapped." } ], "code": "SFP", "display": "Steam Flush Pressure Pulse" }, { "code": "THR", "display": "Thermal" }, { "code": "TRB", "display": "Tray/Basin" }, { "code": "UTL", "display": "Utensil Wash" }, { "extension": [ { "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments", "valueString": "A Wrap/SFPP cycle uses steam pulses instead of a vacuum during the conditioning phase of the cycle when the supply item is unwrapped." } ], "code": "WFP", "display": "Wrap/Steam Flush Pressure Pulse (Wrap/SFPP)" } ] }
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.