STU 3 Ballot

This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0356.cs.xml

Raw XML (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0356 ( Alternate Character Set Handling Scheme)

<CodeSystem xmlns="http://hl7.org/fhir">
  <id value="v2-0356"/>
  <meta>
    <profile value="http://hl7.org/fhir/StructureDefinition/codesystem-shareable-definition"/>
  </meta>
  <text>
    <status value="additional"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
      <p>Alternate Character Set Handling Scheme</p>

      <table class="grid">
        <tr>
          <td>
            <b>Code</b>
          </td>
          <td>
            <b>Description</b>
          </td>
          <td>
            <b>Comment</b>
          </td>
          <td>
            <b>Version</b>
          </td>
        </tr>
        <tr>
          <td>2.3
            <a name="2.463"> </a>
          </td>
          <td>The character set switching mode specified in HL7 2.5, section 2.7.2 and section 2.A.46,
               &quot;XPN - extended person name&quot;.</td>
          <td>Note that the escape sequences used in this mode do not use the ASCII &quot;esc&quot;
               character, as defined in ISO 2022-1994. They are &quot;HL7 escape sequences&quot; as first
               defined in HL7 2.3, sec. 2.9.2. (Also, note that sections 2.8.28.6.1and 2.9.2 in HL7 2.3
               correspon</td>
          <td>added v2.3.1</td>
        </tr>
        <tr>
          <td>&lt;null&gt;
            <a name=".60null.62"> </a>
          </td>
          <td>This is the default, indicating that there is no character set switching occurring in
               this message.</td>
          <td>This is the default.</td>
          <td>added v2.3.1</td>
        </tr>
        <tr>
          <td>iso 2022-1994
            <a name="iso2022-1994"> </a>
          </td>
          <td>This standard is titled &quot;Information Technology - Character Code Structure and Extension
               Technique&quot;. .</td>
          <td>This standard specifies an escape sequence from basic one byte character set to specified
               other character set, and vice versa. The escape sequence explicitly specifies what alternate
               character set to be evoked. Note that in this mode, the actual ASCII esc</td>
          <td>added v2.3.1</td>
        </tr>
      </table>

    </div>
  </text>
  <url value="http://hl7.org/fhir/v2/0356"/>
  <identifier>
    <system value="urn:ietf:rfc:3986"/>
    <value value="urn:oid:2.16.840.1.133883.18.216"/>
  </identifier>
  <version value="2.8.2"/>
  <name value="v2 Alternate Character Set Handling Scheme"/>
  <status value="active"/>
  <experimental value="true"/>
  <publisher value="HL7, Inc"/>
  <contact>
    <telecom>
      <system value="other"/>
      <value value="http://hl7.org"/>
    </telecom>
  </contact>
  <description value="FHIR Value set/code system definition for HL7 v2 table 0356 ( Alternate Character Set
     Handling Scheme)"/>
  <caseSensitive value="false"/>
  <valueSet value="http://hl7.org/fhir/ValueSet/v2-0356"/>
  <content value="complete"/>
  <concept>
    <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments">
      <valueString value="Note that the escape sequences used in this mode do not use the ASCII &quot;esc&quot;
         character, as defined in ISO 2022-1994. They are &quot;HL7 escape sequences&quot; as first
         defined in HL7 2.3, sec. 2.9.2. (Also, note that sections 2.8.28.6.1and 2.9.2 in HL7 2.3
         correspon"/>
    </extension>
    <code value="2.3"/>
    <display value="The character set switching mode specified in HL7 2.5, section 2.7.2 and section 2.A.46,
       &quot;XPN - extended person name&quot;."/>
  </concept>
  <concept>
    <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments">
      <valueString value="This is the default."/>
    </extension>
    <code value="&lt;null&gt;"/>
    <display value="This is the default, indicating that there is no character set switching occurring in
       this message."/>
  </concept>
  <concept>
    <extension url="http://hl7.org/fhir/StructureDefinition/valueset-comments">
      <valueString value="This standard specifies an escape sequence from basic one byte character set to specified
         other character set, and vice versa. The escape sequence explicitly specifies what alternate
         character set to be evoked. Note that in this mode, the actual ASCII esc"/>
    </extension>
    <code value="ISO 2022-1994"/>
    <display value="This standard is titled &quot;Information Technology - Character Code Structure and Extension
       Technique&quot;. ."/>
  </concept>
</CodeSystem>

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.