STU 3 Ballot

This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R4 R3

V2-0174.cs.json

Raw JSON (canonical form)

FHIR Value set/code system definition for HL7 v2 table 0174 ( Nature of Service/Test/Observation)

{
  "resourceType": "CodeSystem",
  "id": "v2-0174",
  "meta": {
    "profile": [
      "http://hl7.org/fhir/StructureDefinition/codesystem-shareable-definition"
    ]
  },
  "text": {
    "status": "additional",
    "div": "<div>!-- Snipped for Brevity --></div>"
  },
  "url": "http://hl7.org/fhir/v2/0174",
  "identifier": {
    "system": "urn:ietf:rfc:3986",
    "value": "urn:oid:2.16.840.1.133883.18.90"
  },
  "version": "2.8.2",
  "name": "v2 Nature of Service/Test/Observation",
  "status": "active",
  "experimental": true,
  "publisher": "HL7, Inc",
  "contact": [
    {
      "telecom": [
        {
          "system": "other",
          "value": "http://hl7.org"
        }
      ]
    }
  ],
  "description": "FHIR Value set/code system definition for HL7 v2 table 0174 ( Nature of Service/Test/Observation)",
  "caseSensitive": false,
  "valueSet": "http://hl7.org/fhir/ValueSet/v2-0174",
  "content": "complete",
  "concept": [
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
          "valueString": "can be associated with one or more OM4 (specimen) segments<p>a single direct observation and would usually be associated with an OM2 and/or OM3 segments"
        }
      ],
      "code": "A",
      "display": "Atomic service/test/observation (test code or treatment code)",
      "designation": [
        {
          "language": "de",
          "value": "Einzeluntersuchung"
        },
        {
          "language": "nl",
          "value": "Atomische service/test/observatie (testcode of behandelingcode)"
        }
      ]
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
          "valueString": "can be associated with one or more OM4 (specimen) segments<p>a derived quantity and would usually be associated with an OM6 segment"
        }
      ],
      "code": "C",
      "display": "Single observation calculated via a rule or formula from other independent observations (e.g. Alveolar-arterial ratio, cardiac output)",
      "designation": [
        {
          "language": "de",
          "value": "Berechnetes Einzelergebnis"
        },
        {
          "language": "nl",
          "value": "Enkelvoudige observatie berekend via regels of formule uit andere onafhankelijke observaties (bijv. Alveolair--arteriële gradiënt, hart-minuut-volume)"
        }
      ]
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
          "valueString": "can be associated with one or more OM4 (specimen) segments<p>See comment for value S"
        }
      ],
      "code": "F",
      "display": "Functional procedure that may consist of one or more interrelated measures (e.g. glucose tolerance test, creatinine clearance), usually done at different times and/or on different specimens",
      "designation": [
        {
          "language": "de",
          "value": "Funktionstest"
        },
        {
          "language": "nl",
          "value": "Functionele procedure die kan bestaan uit een of meer gerelateerde metingen (bijv. glucosetolerantietest, creatinineklaring),  meestal uitgevoerd op verschillende momenten en/of verschillende monsters"
        }
      ]
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
          "valueString": "can be associated with one or more OM4 (specimen) segments<p>See comment for value S"
        }
      ],
      "code": "P",
      "display": "Profile or battery consisting of many independent atomic observations (e.g. SMA12, electrolytes), usually done at one instrument on one specimen",
      "designation": [
        {
          "language": "de",
          "value": "Batterieanordnung"
        },
        {
          "language": "nl",
          "value": "Profiel of battery bestaande uit vele onafhankelijke atomische observaties (bijv. SMA12, electrolyten), meestal met één instrument op één monster"
        }
      ]
    },
    {
      "extension": [
        {
          "url": "http://hl7.org/fhir/StructureDefinition/valueset-comments",
          "valueString": "can be associated with one or more OM4 (specimen) segments<p>Codes P, F, and S identify sets (batteries) and should be associated with an OM5 segment that defines the list of elements.  The definitions for the contained elements would have to be sent in o"
        }
      ],
      "code": "S",
      "display": "Superset-a set of batteries or procedures ordered under a single code unit but processed as separate batteries (e.g. routines = CBC, UA, electrolytes)<p>This set indicates that the code being described is used to order multiple service/test/observation b",
      "designation": [
        {
          "language": "de",
          "value": "Latte von mehreren Batterieanforderungen (Aufnahmelatte)"
        },
        {
          "language": "nl",
          "value": "Superset--een set batteries of procedures aangevraagd onder een enkele aanvraagcode maar behandeld als afzonderlijke batteries (bijv. routines = CBC, UA, electrolyten); Deze set geeft aan dat de bedoelde code wordt gebruikt voor het aanvragen van meerdere services/tests/observaties"
        }
      ]
    }
  ]
}

Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.