This page is part of the FHIR Specification (v1.6.0: STU 3 Ballot 4). The current version which supercedes this version is 5.0.0. For a full list of available versions, see the Directory of published versions . Page versions: R5 R4B R4 R3
Oxygen Saturation Example (DeviceMetricObservation profile)
@prefix fhir: <http://hl7.org/fhir/> . @prefix owl: <http://www.w3.org/2002/07/owl#> . @prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> . @prefix xsd: <http://www.w3.org/2001/XMLSchema#> . # - resource ------------------------------------------------------------------- <http://hl7.org/fhir/Observation/satO2> a fhir:Observation; fhir:nodeRole fhir:treeRoot; fhir:Resource.id [ fhir:value "satO2"]; fhir:DomainResource.text [ fhir:Narrative.status [ fhir:value "generated" ]; fhir:Narrative.div "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p><b>Generated Narrative with Details</b></p><p><b>id</b>: satO2</p><p><b>identifier</b>: o1223435-10</p><p><b>status</b>: final</p><p><b>code</b>: MDC_PULS_OXIM_SAT_O2 <span>(Details : {https://rtmms.nist.gov code '150456' = '??', given as 'MDC_PULS_OXIM_SAT_O2'})</span></p><p><b>subject</b>: <a>Patient/example</a></p><p><b>effective</b>: 05/12/2014 9:30:10 AM</p><p><b>value</b>: 95 %<span> (Details: https://rtmms.nist.gov code 262688 = '??')</span></p><p><b>interpretation</b>: Normal (applies to non-numeric results) <span>(Details : {http://hl7.org/fhir/v2/0078 code 'N' = 'Normal', given as 'Normal'})</span></p><p><b>device</b>: <a>DeviceMetric/example</a></p><h3>ReferenceRanges</h3><table><tr><td>-</td><td><b>Low</b></td><td><b>High</b></td></tr><tr><td>*</td><td>90 %<span> (Details: https://rtmms.nist.gov code 262688 = '??')</span></td><td>99 %<span> (Details: https://rtmms.nist.gov code 262688 = '??')</span></td></tr></table></div>" ]; fhir:Observation.identifier [ fhir:index 0; fhir:Identifier.system [ fhir:value "http://goodcare.org/observation/id" ]; fhir:Identifier.value [ fhir:value "o1223435-10" ] ]; fhir:Observation.status [ fhir:value "final"]; fhir:Observation.code [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Coding.code [ fhir:value "150456" ]; fhir:Coding.display [ fhir:value "MDC_PULS_OXIM_SAT_O2" ] ] ]; fhir:Observation.subject [ fhir:link <http://hl7.org/fhir/Patient/example>; fhir:Reference.reference [ fhir:value "Patient/example" ] ]; fhir:Observation.effectiveDateTime [ fhir:value "2014-12-05T09:30:10+01:00"^^xsd:dateTime]; fhir:Observation.valueQuantity [ fhir:Quantity.value [ fhir:value "95"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "%" ]; fhir:Quantity.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Quantity.code [ fhir:value "262688" ] ]; fhir:Observation.interpretation [ fhir:CodeableConcept.coding [ fhir:index 0; fhir:Coding.system [ fhir:value "http://hl7.org/fhir/v2/0078" ]; fhir:Coding.code [ fhir:value "N" ]; fhir:Coding.display [ fhir:value "Normal" ] ]; fhir:CodeableConcept.text [ fhir:value "Normal (applies to non-numeric results)" ] ]; fhir:Observation.device [ fhir:link <http://hl7.org/fhir/DeviceMetric/example>; fhir:Reference.reference [ fhir:value "DeviceMetric/example" ] ]; fhir:Observation.referenceRange [ fhir:index 0; fhir:Observation.referenceRange.low [ fhir:Quantity.value [ fhir:value "90"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "%" ]; fhir:Quantity.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Quantity.code [ fhir:value "262688" ] ]; fhir:Observation.referenceRange.high [ fhir:Quantity.value [ fhir:value "99"^^xsd:decimal ]; fhir:Quantity.unit [ fhir:value "%" ]; fhir:Quantity.system [ fhir:value "https://rtmms.nist.gov" ]; fhir:Quantity.code [ fhir:value "262688" ] ] ] . <http://hl7.org/fhir/Patient/example> a fhir:Patient . <http://hl7.org/fhir/DeviceMetric/example> a fhir:DeviceMetric . # -------------------------------------------------------------------------------------
Usage note: every effort has been made to ensure that the examples are correct and useful, but they are not a normative part of the specification.